Implications of temporal sampling in voltage imaging microscopy

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Czuchnowski, Jakub, Mertz, Jerome
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866915758683979776
author Czuchnowski, Jakub
Mertz, Jerome
author_facet Czuchnowski, Jakub
Mertz, Jerome
contents Significance: Voltage imaging microscopy has emerged as a powerful tool to investigate neural activity both in vivo and in vitro. Various imaging approaches have been developed, including point-scanning, line-scanning and wide-field microscopes, however the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. Aim: To provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. Approach: We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Results: Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Conclusions: Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.
format Preprint
id arxiv_https___arxiv_org_abs_2601_20236
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Implications of temporal sampling in voltage imaging microscopy
Czuchnowski, Jakub
Mertz, Jerome
Optics
Neurons and Cognition
Quantitative Methods
Significance: Voltage imaging microscopy has emerged as a powerful tool to investigate neural activity both in vivo and in vitro. Various imaging approaches have been developed, including point-scanning, line-scanning and wide-field microscopes, however the effects of their different temporal sampling methods on signal fidelity have not yet been fully investigated. Aim: To provide an analysis of the inherent advantages and disadvantages of temporal sampling in scanning and wide-field microscopes and their effect on the fidelity of voltage spike detection. Approach: We develop a mathematical framework based on a mixture of analytical modeling and computer simulations with Monte-Carlo approaches. Results: Scanning microscopes outperform wide-field microscopes in low signal-to-noise conditions and when only a small subset of spikes needs to be detected. Wide-field microscopes outperform scanning microscopes when the measurement is temporally undersampled and a large fraction of the spikes needs to be detected. Both modalities converge in performance as sampling increases and the frame rate reaches the decay rate of the voltage indicator. Conclusions: Our work provides guidance for the selection of optimal temporal sampling parameters for voltage imaging. Most importantly it advises against using scanning voltage imaging microscopes at frame rates below 500 Hz.
title Implications of temporal sampling in voltage imaging microscopy
topic Optics
Neurons and Cognition
Quantitative Methods
url https://arxiv.org/abs/2601.20236