High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Adamič, M., Beretta, M., Camilleri, J., Capelli, C., Dobbs, M. A., Elleflot, T., Fujikawa, B. K., Kolomensky, Yu. G., Mayer, D., Montgomery, J., Novosad, V., Sindhwad, A. M., Singh, V., Smecher, G., Suzuki, A., Welliver, B.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866914295631052800
author Adamič, M.
Beretta, M.
Camilleri, J.
Capelli, C.
Dobbs, M. A.
Elleflot, T.
Fujikawa, B. K.
Kolomensky, Yu. G.
Mayer, D.
Montgomery, J.
Novosad, V.
Sindhwad, A. M.
Singh, V.
Smecher, G.
Suzuki, A.
Welliver, B.
author_facet Adamič, M.
Beretta, M.
Camilleri, J.
Capelli, C.
Dobbs, M. A.
Elleflot, T.
Fujikawa, B. K.
Kolomensky, Yu. G.
Mayer, D.
Montgomery, J.
Novosad, V.
Sindhwad, A. M.
Singh, V.
Smecher, G.
Suzuki, A.
Welliver, B.
contents The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by $\sim$1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of $\sim$100 $μ$s, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMux) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor. Each multiplexing readout module comprises ten superconducting resonators in the MHz range and a superconducting quantum interference device (SQUID), interfaced to high-bandwidth field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency feedback.
format Preprint
id arxiv_https___arxiv_org_abs_2601_23106
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches
Adamič, M.
Beretta, M.
Camilleri, J.
Capelli, C.
Dobbs, M. A.
Elleflot, T.
Fujikawa, B. K.
Kolomensky, Yu. G.
Mayer, D.
Montgomery, J.
Novosad, V.
Sindhwad, A. M.
Singh, V.
Smecher, G.
Suzuki, A.
Welliver, B.
Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
Nuclear Experiment
The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at $\sim$10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by $\sim$1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of $\sim$100 $μ$s, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMux) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor. Each multiplexing readout module comprises ten superconducting resonators in the MHz range and a superconducting quantum interference device (SQUID), interfaced to high-bandwidth field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency feedback.
title High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches
topic Instrumentation and Detectors
Instrumentation and Methods for Astrophysics
Nuclear Experiment
url https://arxiv.org/abs/2601.23106