Angle dependent dose transformer algorithm for fast proton therapy dose calculations

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Stryja, Mikołaj, Lathouwers, Danny, Perkó, Zoltán
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866918343875756032
author Stryja, Mikołaj
Lathouwers, Danny
Perkó, Zoltán
author_facet Stryja, Mikołaj
Lathouwers, Danny
Perkó, Zoltán
contents Accurate 3D dose calculation for Pencil Beam Scanning Proton Therapy (PBSPT) is typically performed with Monte Carlo (MC) engines, but their runtimes limit adaptive workflows and repeated evaluations. Current deep-learning proton dose engines often require orthogonality between proton rays and the CT grid, forcing computationally expensive beamlet-wise 3D reinterpolation. We propose the Angle-dependent Dose Transformer Algorithm (ADoTA), which eliminates grid rotation by augmenting the model input with a fast analytical beamlet-shape projection that explicitly encodes beam direction. The model was trained on CT data from 108 patients to predict beamlet dose distributions for initial energies of $70$--$270\,\mathrm{MeV}$ over an $80\times110\,\mathrm{mm}^2$ field, and tested on an independent cohort of 50 patients. On the test set, gamma pass rates $(1\%,3\,\mathrm{mm})$ were $99.40\pm0.86\%$ (thorax) and $99.87\pm0.23\%$ (abdomen/pelvis). Single-beamlet inference took $1.72\pm0.8\,\mathrm{ms}$. By avoiding reinterpolation, end-to-end 3D dose computation was reduced by $\approx86\%$ relative to the fastest published reinterpolation-based methods. For full treatment plans, gamma pass rates $Γ(2\%,2\,\mathrm{mm})$ with a 10\% dose cut-off reached $98.4\%$ (lung) and $98.9\%$ (prostate). ADoTA provides an angle-aware deep-learning proton dose engine that preserves MC-level accuracy across heterogeneous anatomies while substantially reducing computational overhead.
format Preprint
id arxiv_https___arxiv_org_abs_2602_04375
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Angle dependent dose transformer algorithm for fast proton therapy dose calculations
Stryja, Mikołaj
Lathouwers, Danny
Perkó, Zoltán
Medical Physics
Accurate 3D dose calculation for Pencil Beam Scanning Proton Therapy (PBSPT) is typically performed with Monte Carlo (MC) engines, but their runtimes limit adaptive workflows and repeated evaluations. Current deep-learning proton dose engines often require orthogonality between proton rays and the CT grid, forcing computationally expensive beamlet-wise 3D reinterpolation. We propose the Angle-dependent Dose Transformer Algorithm (ADoTA), which eliminates grid rotation by augmenting the model input with a fast analytical beamlet-shape projection that explicitly encodes beam direction. The model was trained on CT data from 108 patients to predict beamlet dose distributions for initial energies of $70$--$270\,\mathrm{MeV}$ over an $80\times110\,\mathrm{mm}^2$ field, and tested on an independent cohort of 50 patients. On the test set, gamma pass rates $(1\%,3\,\mathrm{mm})$ were $99.40\pm0.86\%$ (thorax) and $99.87\pm0.23\%$ (abdomen/pelvis). Single-beamlet inference took $1.72\pm0.8\,\mathrm{ms}$. By avoiding reinterpolation, end-to-end 3D dose computation was reduced by $\approx86\%$ relative to the fastest published reinterpolation-based methods. For full treatment plans, gamma pass rates $Γ(2\%,2\,\mathrm{mm})$ with a 10\% dose cut-off reached $98.4\%$ (lung) and $98.9\%$ (prostate). ADoTA provides an angle-aware deep-learning proton dose engine that preserves MC-level accuracy across heterogeneous anatomies while substantially reducing computational overhead.
title Angle dependent dose transformer algorithm for fast proton therapy dose calculations
topic Medical Physics
url https://arxiv.org/abs/2602.04375