The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , , , , , , , , , , , , |
|---|---|
| Format: | Preprint |
| Publié: |
2026
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866910161350688768 |
|---|---|
| author | Gavin, Andrew S. Balzer, Matthias Chilingaryan, Suren Henning, Reyco Kopmann, Andreas Mertens, Susanne Mostafa, Jalal Simon, Frank Jerome, Nicholas Tan Tcherniakhovski, Denis Urban, Korbinian Wilkerson, John F. Wüstling, Sascha |
| author_facet | Gavin, Andrew S. Balzer, Matthias Chilingaryan, Suren Henning, Reyco Kopmann, Andreas Mertens, Susanne Mostafa, Jalal Simon, Frank Jerome, Nicholas Tan Tcherniakhovski, Denis Urban, Korbinian Wilkerson, John F. Wüstling, Sascha |
| contents | The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for the experimental signature of keV scale sterile neutrinos. The TRISTAN detector upgrade consists of performing precision electron spectroscopy with over 1000 silicon drift detector pixels, each responsible for recording event rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges with a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2602_04976 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade Gavin, Andrew S. Balzer, Matthias Chilingaryan, Suren Henning, Reyco Kopmann, Andreas Mertens, Susanne Mostafa, Jalal Simon, Frank Jerome, Nicholas Tan Tcherniakhovski, Denis Urban, Korbinian Wilkerson, John F. Wüstling, Sascha Instrumentation and Detectors The TRISTAN detector is an upgrade to the KATRIN experiment to enable a differential measurement of the tritium $β$-decay spectrum to search for the experimental signature of keV scale sterile neutrinos. The TRISTAN detector upgrade consists of performing precision electron spectroscopy with over 1000 silicon drift detector pixels, each responsible for recording event rates of $10^5$ counts per second. A project specific data acquisition (DAQ) system is developed to meet the experimental challenges with a remote analog to digital conversion (RADC) design. In this work, the conceptual design of the RADC DAQ is presented along with the built system for operating the TRISTAN detector upgrade. The system includes flexible signal processing logic and data management that is optimized for the high-rate precision measurement. |
| title | The Remote Analog to Digital Conversion DAQ System for the TRISTAN Detector Upgrade |
| topic | Instrumentation and Detectors |
| url | https://arxiv.org/abs/2602.04976 |