contents Purpose: To investigate whether an AI-based method can detect subtle inter-fraction changes in MR-Linac images acquired during radiotherapy and explore the broader potential of MRLinac imaging. Methods: This retrospective study included longitudinal 0.35T MR-Linac images from 761 patients. To identify temporal changes, we employed a deep learning model using temporal ordering via pairwise comparison, previously shown effective for longitudinal imaging studies. The model was trained using first-to-last fraction pairs (F1-FL) and all pairs (All-pairs). Performance was assessed using quantitative metrics (accuracy and AUC) and compared against a radiologist's performance. Qualitative evaluation was performed using saliency maps, which identify anatomical regions associated with temporal imaging changes. Results: The F1-FL model demonstrated high performance (AUC=0.99, accuracy=0.95) and outperformed the radiologist in temporal ordering task. The All-pairs model also showed high performance (AUC=0.97, accuracy=0.91). Regions contributing to predictions included the prostate, bladder, and pubic symphysis. The performance was correlated to fractional intervals and was reduced for non-radiation-exposed timepoints (Sim and F1), suggesting that observed changes may reflect both temporal variation and radiation exposure. Conclusion: MR-Linac imaging appears capable of capturing subtle changes during prostate radiotherapy that can be detected by AI models, even over approximately two-day intervals. The model's high performance, together with quantitative and qualitative analyses, supports a potential role for MR-Linac in clinical applications beyond image guidance.
format Preprint
id arxiv_https___arxiv_org_abs_2602_04983
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle AI-Based Detection of Temporal Changes in MR-Linac Images Acquired During Routine Prostate Radiotherapy
Park, Seungbin
Wang, Peilin
Pennell, Ryan
Weg, Emily S.
Nagar, Himanshu
McClure, Timothy
Sabuncu, Mert R.
Margolis, Daniel
Kim, Heejong
Image and Video Processing
Artificial Intelligence
Machine Learning
Purpose: To investigate whether an AI-based method can detect subtle inter-fraction changes in MR-Linac images acquired during radiotherapy and explore the broader potential of MRLinac imaging. Methods: This retrospective study included longitudinal 0.35T MR-Linac images from 761 patients. To identify temporal changes, we employed a deep learning model using temporal ordering via pairwise comparison, previously shown effective for longitudinal imaging studies. The model was trained using first-to-last fraction pairs (F1-FL) and all pairs (All-pairs). Performance was assessed using quantitative metrics (accuracy and AUC) and compared against a radiologist's performance. Qualitative evaluation was performed using saliency maps, which identify anatomical regions associated with temporal imaging changes. Results: The F1-FL model demonstrated high performance (AUC=0.99, accuracy=0.95) and outperformed the radiologist in temporal ordering task. The All-pairs model also showed high performance (AUC=0.97, accuracy=0.91). Regions contributing to predictions included the prostate, bladder, and pubic symphysis. The performance was correlated to fractional intervals and was reduced for non-radiation-exposed timepoints (Sim and F1), suggesting that observed changes may reflect both temporal variation and radiation exposure. Conclusion: MR-Linac imaging appears capable of capturing subtle changes during prostate radiotherapy that can be detected by AI models, even over approximately two-day intervals. The model's high performance, together with quantitative and qualitative analyses, supports a potential role for MR-Linac in clinical applications beyond image guidance.
title AI-Based Detection of Temporal Changes in MR-Linac Images Acquired During Routine Prostate Radiotherapy