Hyperbolic statistical inference for Treatment Effects with Circular biomarker of astigmatism

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Banerjee, Buddhananda, Biswas, Surojit, Prusty, Daitari
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866911431528546304
author Banerjee, Buddhananda
Biswas, Surojit
Prusty, Daitari
author_facet Banerjee, Buddhananda
Biswas, Surojit
Prusty, Daitari
contents Circular biomarkers arise naturally in many biomedical applications, particularly in ophthalmology, where angular measurements such as astigmatism are routinely recorded. Similar directional variables also occur in the study of human body rotations, including movements of the hand, waist, neck, and lower limbs. Motivated by a clinical dataset comprising angular measurements of astigmatism induced by two cataract surgery procedures, we propose a novel two-sample testing framework for circular data grounded in hyperbolic geometry. Assuming von Mises distributions with either common or group-specific concentration parameters, we embed the corresponding parameter spaces into the Poincaré disk, an open unit disk endowed with the Poincaré metric.Under this construction, each von Mises distribution is mapped uniquely to a point in the Poincaré disk, yielding a continuous geometric representation that preserves the intrinsic structure of the parameter space. This embedding enables direct comparison of group distributions via hyperbolic distances, leading to natural and interpretable test statistics. We develop permutation-based tests for the common concentration case and bootstrap-based procedures for unequal concentrations. Extensive simulation studies demonstrate stable empirical size, strong consistency, and superior asymptotic power compared with existing competing methods. The proposed methodology is illustrated through a detailed analysis of the cataract surgery dataset, including a clinically informed restructuring of the original observations. The results highlight the practical advantages of incorporating hyperbolic geometry into the analysis of circular biomedical data and underscore the potential of geometry-aware inference for directional biomarkers.
format Preprint
id arxiv_https___arxiv_org_abs_2602_07740
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Hyperbolic statistical inference for Treatment Effects with Circular biomarker of astigmatism
Banerjee, Buddhananda
Biswas, Surojit
Prusty, Daitari
Methodology
Circular biomarkers arise naturally in many biomedical applications, particularly in ophthalmology, where angular measurements such as astigmatism are routinely recorded. Similar directional variables also occur in the study of human body rotations, including movements of the hand, waist, neck, and lower limbs. Motivated by a clinical dataset comprising angular measurements of astigmatism induced by two cataract surgery procedures, we propose a novel two-sample testing framework for circular data grounded in hyperbolic geometry. Assuming von Mises distributions with either common or group-specific concentration parameters, we embed the corresponding parameter spaces into the Poincaré disk, an open unit disk endowed with the Poincaré metric.Under this construction, each von Mises distribution is mapped uniquely to a point in the Poincaré disk, yielding a continuous geometric representation that preserves the intrinsic structure of the parameter space. This embedding enables direct comparison of group distributions via hyperbolic distances, leading to natural and interpretable test statistics. We develop permutation-based tests for the common concentration case and bootstrap-based procedures for unequal concentrations. Extensive simulation studies demonstrate stable empirical size, strong consistency, and superior asymptotic power compared with existing competing methods. The proposed methodology is illustrated through a detailed analysis of the cataract surgery dataset, including a clinically informed restructuring of the original observations. The results highlight the practical advantages of incorporating hyperbolic geometry into the analysis of circular biomedical data and underscore the potential of geometry-aware inference for directional biomarkers.
title Hyperbolic statistical inference for Treatment Effects with Circular biomarker of astigmatism
topic Methodology
url https://arxiv.org/abs/2602.07740