Overcoming sensitivity-bandwidth trade-off in mid-infrared spectroscopy by a microresonator-anchored swept laser

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Cai, Zhaoyu, Wang, Zihao, Ding, Yulei, Wang, Yifei, Wang, Chengjiu, Yang, Changxi, Guo, Yanan, Yan, Jianchang, Wang, Junxi, Liu, Xun, Li, Jiangtao, Zhao, Ruocan, Xue, Xianghui, Bao, Chengying
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911431568392192
author Cai, Zhaoyu
Wang, Zihao
Ding, Yulei
Wang, Yifei
Wang, Chengjiu
Yang, Changxi
Guo, Yanan
Yan, Jianchang
Wang, Junxi
Liu, Xun
Li, Jiangtao
Zhao, Ruocan
Xue, Xianghui
Bao, Chengying
author_facet Cai, Zhaoyu
Wang, Zihao
Ding, Yulei
Wang, Yifei
Wang, Chengjiu
Yang, Changxi
Guo, Yanan
Yan, Jianchang
Wang, Junxi
Liu, Xun
Li, Jiangtao
Zhao, Ruocan
Xue, Xianghui
Bao, Chengying
contents Optical frequency combs have revolutionized high-precision spectroscopy, yet an intrinsic trade-off between spectroscopic signal-to-noise ratio (sSNR) and measurement bandwidth ($B$) fundamentally constrains sensitive, broadband measurements. While broadband swept lasers offer a potential solution, generating broadband, ultrafast and linearly sweeping lasers with a narrow linewidth remains a significant challenge, particularly in the fingerprint mid-infrared (mid-IR) band. Here we overcome this limitation by using a microresonator-anchored ultrafast sweeping Fourier domain mode-locked (FDML) laser for mid-IR spectroscopy. We introduce a dual-microresonator-anchor approach: a microcomb provides frequency calibration and a high-Q microresonator resolves the instantaneous FDML lasing lineshape. The strategy enables accurate correction of the FDML laser's sweep nonlinearity and broad linewidth in the near-IR, allowing the FDML laser to function as a high-fidelity mid-IR light via difference frequency generation. The system achieves a record sSNR$\times$$B$ of 1.3$\times$10$^5$ THz$\cdot \sqrt{\rm Hz}$ and methane sensing precision of 9 ppb$\cdot$m$\cdot$$\sqrt{\rm s}$, while retaining GHz resolution to distinguish methane isotope. We further demonstrate broadband, coherent swept laser phase spectroscopy in the mid-IR, tolerating losses up to 78 dB. This work leverages advances in integrated photonics to overcome the fundamental limitations of precision spectroscopy, paving the way for next-generation, broadband, and ultra-sensitive mid-IR spectroscopic sensing systems.
format Preprint
id arxiv_https___arxiv_org_abs_2602_07757
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Overcoming sensitivity-bandwidth trade-off in mid-infrared spectroscopy by a microresonator-anchored swept laser
Cai, Zhaoyu
Wang, Zihao
Ding, Yulei
Wang, Yifei
Wang, Chengjiu
Yang, Changxi
Guo, Yanan
Yan, Jianchang
Wang, Junxi
Liu, Xun
Li, Jiangtao
Zhao, Ruocan
Xue, Xianghui
Bao, Chengying
Optics
Optical frequency combs have revolutionized high-precision spectroscopy, yet an intrinsic trade-off between spectroscopic signal-to-noise ratio (sSNR) and measurement bandwidth ($B$) fundamentally constrains sensitive, broadband measurements. While broadband swept lasers offer a potential solution, generating broadband, ultrafast and linearly sweeping lasers with a narrow linewidth remains a significant challenge, particularly in the fingerprint mid-infrared (mid-IR) band. Here we overcome this limitation by using a microresonator-anchored ultrafast sweeping Fourier domain mode-locked (FDML) laser for mid-IR spectroscopy. We introduce a dual-microresonator-anchor approach: a microcomb provides frequency calibration and a high-Q microresonator resolves the instantaneous FDML lasing lineshape. The strategy enables accurate correction of the FDML laser's sweep nonlinearity and broad linewidth in the near-IR, allowing the FDML laser to function as a high-fidelity mid-IR light via difference frequency generation. The system achieves a record sSNR$\times$$B$ of 1.3$\times$10$^5$ THz$\cdot \sqrt{\rm Hz}$ and methane sensing precision of 9 ppb$\cdot$m$\cdot$$\sqrt{\rm s}$, while retaining GHz resolution to distinguish methane isotope. We further demonstrate broadband, coherent swept laser phase spectroscopy in the mid-IR, tolerating losses up to 78 dB. This work leverages advances in integrated photonics to overcome the fundamental limitations of precision spectroscopy, paving the way for next-generation, broadband, and ultra-sensitive mid-IR spectroscopic sensing systems.
title Overcoming sensitivity-bandwidth trade-off in mid-infrared spectroscopy by a microresonator-anchored swept laser
topic Optics
url https://arxiv.org/abs/2602.07757