Geometry-driven impact of photosensor placement on S2-based XY reconstruction in a dual-phase argon TPC

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Yin, Jilong, Wang, Yi
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912890261340160
author Yin, Jilong
Wang, Yi
author_facet Yin, Jilong
Wang, Yi
contents Accurate reconstruction of the horizontal vertex $(x,y)$ from the S2 electroluminescence pattern is essential for fiducialization and background rejection in dual-phase argon time projection chambers. In this work, we perform a Geant4-based simulation study using the G4DS framework to investigate how detector geometry, in particular the distance between the top photodetector plane and the gas pocket, impacts S2-based XY reconstruction. A compact dual-phase argon TPC instrumented with seven Hamamatsu R8520-506 PMTs is simulated with electron recoils at 41.5 keV (corresponding to the ${}^{83m}\mathrm{Kr}$ calibration energy), as well as 1.0 keV to probe the low-S2 regime. The PMT array height is scanned from 0 mm to 50 mm, and XY positions are reconstructed using a geometrical solid-angle (GSA) method with the S2 emission modeled by 1 mm-thick slices across the 7 mm gas pocket. The results show a clear non-monotonic dependence of reconstruction bias and resolution on PMT height, driven by the trade-off between S2 light sharing and photon statistics. These findings provide guidance for geometry optimization in future low-threshold dual-phase argon detectors and will be validated with upcoming prototype measurements.
format Preprint
id arxiv_https___arxiv_org_abs_2602_08402
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Geometry-driven impact of photosensor placement on S2-based XY reconstruction in a dual-phase argon TPC
Yin, Jilong
Wang, Yi
Instrumentation and Detectors
High Energy Physics - Experiment
Accurate reconstruction of the horizontal vertex $(x,y)$ from the S2 electroluminescence pattern is essential for fiducialization and background rejection in dual-phase argon time projection chambers. In this work, we perform a Geant4-based simulation study using the G4DS framework to investigate how detector geometry, in particular the distance between the top photodetector plane and the gas pocket, impacts S2-based XY reconstruction. A compact dual-phase argon TPC instrumented with seven Hamamatsu R8520-506 PMTs is simulated with electron recoils at 41.5 keV (corresponding to the ${}^{83m}\mathrm{Kr}$ calibration energy), as well as 1.0 keV to probe the low-S2 regime. The PMT array height is scanned from 0 mm to 50 mm, and XY positions are reconstructed using a geometrical solid-angle (GSA) method with the S2 emission modeled by 1 mm-thick slices across the 7 mm gas pocket. The results show a clear non-monotonic dependence of reconstruction bias and resolution on PMT height, driven by the trade-off between S2 light sharing and photon statistics. These findings provide guidance for geometry optimization in future low-threshold dual-phase argon detectors and will be validated with upcoming prototype measurements.
title Geometry-driven impact of photosensor placement on S2-based XY reconstruction in a dual-phase argon TPC
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2602.08402