Test-retest Reliability of Psychophysical Tasks Using Structured Light-Induced Entoptic Phenomena

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Singh, Taranjit, Kulmaganbetov, Mukhit, Wang, Zhangting, Pushin, Dmitry, Thompson, Benjamin, Silva, Andrew, Mungalsingh, Melanie, Salehi, Iman, Garrad, Davis, Cory, David, Sarenac, Dusan
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866918328793038848
author Singh, Taranjit
Kulmaganbetov, Mukhit
Wang, Zhangting
Pushin, Dmitry
Thompson, Benjamin
Silva, Andrew
Mungalsingh, Melanie
Salehi, Iman
Garrad, Davis
Cory, David
Sarenac, Dusan
author_facet Singh, Taranjit
Kulmaganbetov, Mukhit
Wang, Zhangting
Pushin, Dmitry
Thompson, Benjamin
Silva, Andrew
Mungalsingh, Melanie
Salehi, Iman
Garrad, Davis
Cory, David
Sarenac, Dusan
contents Structured light (SL)-induced polarization perception presents a promising method for the early detection of macular diseases such as age-related macular degeneration. We investigated the test-retest reliability of a psychophysical task using SL-based stimuli to induce entoptic patterns in individuals with healthy vision. Twenty-eight participants underwent thorough eye examinations to confirm they had healthy eyes and good vision (logMAR BCVA ~0.00). Of these, 25 participants (n=50 eyes) aged 21 to 75 completed two identical tasks separated by 1 to 14 days. Using SL-based stimuli that produced a rotating entoptic pattern containing 22 azimuthal brushes, we measured the retinal eccentricity threshold $R_T$ at which participants could reliably identify the direction of rotation by varying the size of a central obstruction. This threshold reflects the visual angle of the pattern for each participant. We calculated the reliability coefficient (intraclass correlation coefficient, ICC) using a two-way mixed-effects model and conducted a Bland-Altman analysis to assess test-retest reliability. The ICC was 0.83 [95% CI: 0.62 - 0.93] for right eyes (RE) and 0.93 [95% CI: 0.84 - 0.97] for left eyes (LE), indicating good reliability. The Bland-Altman analysis showed a mean difference of -0.32° (SD: 1.51) and -0.12° (SD: 1.03) for RE and LE respectively between the first and second sessions, with limits of agreement ranging from -3.28° to 2.64° and -2.14° to 1.89° for RE and LE respectively, confirming strong agreement and no significant bias. These results demonstrate that SL-based psychophysical tasks are a reliable method for assessing polarization perception, potentially improving screening for diseases affecting macular health.
format Preprint
id arxiv_https___arxiv_org_abs_2602_08836
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Test-retest Reliability of Psychophysical Tasks Using Structured Light-Induced Entoptic Phenomena
Singh, Taranjit
Kulmaganbetov, Mukhit
Wang, Zhangting
Pushin, Dmitry
Thompson, Benjamin
Silva, Andrew
Mungalsingh, Melanie
Salehi, Iman
Garrad, Davis
Cory, David
Sarenac, Dusan
Medical Physics
Optics
Structured light (SL)-induced polarization perception presents a promising method for the early detection of macular diseases such as age-related macular degeneration. We investigated the test-retest reliability of a psychophysical task using SL-based stimuli to induce entoptic patterns in individuals with healthy vision. Twenty-eight participants underwent thorough eye examinations to confirm they had healthy eyes and good vision (logMAR BCVA ~0.00). Of these, 25 participants (n=50 eyes) aged 21 to 75 completed two identical tasks separated by 1 to 14 days. Using SL-based stimuli that produced a rotating entoptic pattern containing 22 azimuthal brushes, we measured the retinal eccentricity threshold $R_T$ at which participants could reliably identify the direction of rotation by varying the size of a central obstruction. This threshold reflects the visual angle of the pattern for each participant. We calculated the reliability coefficient (intraclass correlation coefficient, ICC) using a two-way mixed-effects model and conducted a Bland-Altman analysis to assess test-retest reliability. The ICC was 0.83 [95% CI: 0.62 - 0.93] for right eyes (RE) and 0.93 [95% CI: 0.84 - 0.97] for left eyes (LE), indicating good reliability. The Bland-Altman analysis showed a mean difference of -0.32° (SD: 1.51) and -0.12° (SD: 1.03) for RE and LE respectively between the first and second sessions, with limits of agreement ranging from -3.28° to 2.64° and -2.14° to 1.89° for RE and LE respectively, confirming strong agreement and no significant bias. These results demonstrate that SL-based psychophysical tasks are a reliable method for assessing polarization perception, potentially improving screening for diseases affecting macular health.
title Test-retest Reliability of Psychophysical Tasks Using Structured Light-Induced Entoptic Phenomena
topic Medical Physics
Optics
url https://arxiv.org/abs/2602.08836