Measurements of absolute gamma-ray energies using an ultra-high energy resolution magnetic microcalorimeter

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Rodrigues, Matias, Zahir, Mostafa L., Loidl, Martin, Chambon, Lucille, Drenne, Quentin, Müller, Michael, Kempf, Sebastian, Nigron, Etienne, Haddad, Ferid
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866908833218035712
author Rodrigues, Matias
Zahir, Mostafa L.
Loidl, Martin
Chambon, Lucille
Drenne, Quentin
Müller, Michael
Kempf, Sebastian
Nigron, Etienne
Haddad, Ferid
author_facet Rodrigues, Matias
Zahir, Mostafa L.
Loidl, Martin
Chambon, Lucille
Drenne, Quentin
Müller, Michael
Kempf, Sebastian
Nigron, Etienne
Haddad, Ferid
contents We present new measurements of 27 gamma ray energies ranging from 14 keV to 136 keV, obtained using high-energy-resolution magnetic microcalorimeters for energy-dispersive spectrometry. The spectrometer has eight pixels and achieves an energy resolution between 15 and 30 eV across the entire energy range. It faces a cryogenic source sampler with four movable sources. Each source contains a mixture of radionuclides, including Yb-169 and Co-57 used to calibrate the spectrometer and correct its non-linearity. The gamma-ray energies, emitted through the decay of Co-57, Cd-109, Ba-133, Gd-153, Eu-154, Eu-155, Yb-169, Tm-170, Pb-210, Np-239, Am-241 and Am-243, have been reassessed. The lowest absolute uncertainty achieved is 0.13 eV at 105.3 keV, which corresponds to a relative uncertainty of 1.3 ppm. Of the 27 measured gamma rays, the uncertainties of 19 energies were improved with respect to the available literature: 10 by a factor of 5 and 4 by more than one order of magnitude. Good agreement is observed with energies obtained elsewhere by wavelength-dispersive spectrometry. This work significantly improves upon previously reported gamma energies obtained by energy-dispersive spectrometry using semiconductor detectors, thanks to the ultra-high energy resolution of magnetic microcalorimeters.
format Preprint
id arxiv_https___arxiv_org_abs_2602_12836
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Measurements of absolute gamma-ray energies using an ultra-high energy resolution magnetic microcalorimeter
Rodrigues, Matias
Zahir, Mostafa L.
Loidl, Martin
Chambon, Lucille
Drenne, Quentin
Müller, Michael
Kempf, Sebastian
Nigron, Etienne
Haddad, Ferid
Instrumentation and Detectors
We present new measurements of 27 gamma ray energies ranging from 14 keV to 136 keV, obtained using high-energy-resolution magnetic microcalorimeters for energy-dispersive spectrometry. The spectrometer has eight pixels and achieves an energy resolution between 15 and 30 eV across the entire energy range. It faces a cryogenic source sampler with four movable sources. Each source contains a mixture of radionuclides, including Yb-169 and Co-57 used to calibrate the spectrometer and correct its non-linearity. The gamma-ray energies, emitted through the decay of Co-57, Cd-109, Ba-133, Gd-153, Eu-154, Eu-155, Yb-169, Tm-170, Pb-210, Np-239, Am-241 and Am-243, have been reassessed. The lowest absolute uncertainty achieved is 0.13 eV at 105.3 keV, which corresponds to a relative uncertainty of 1.3 ppm. Of the 27 measured gamma rays, the uncertainties of 19 energies were improved with respect to the available literature: 10 by a factor of 5 and 4 by more than one order of magnitude. Good agreement is observed with energies obtained elsewhere by wavelength-dispersive spectrometry. This work significantly improves upon previously reported gamma energies obtained by energy-dispersive spectrometry using semiconductor detectors, thanks to the ultra-high energy resolution of magnetic microcalorimeters.
title Measurements of absolute gamma-ray energies using an ultra-high energy resolution magnetic microcalorimeter
topic Instrumentation and Detectors
url https://arxiv.org/abs/2602.12836