Optimizing Point-of-Care Ultrasound Video Acquisition for Probabilistic Multi-Task Heart Failure Detection

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Saadat, Armin, Hashemi, Nima, Khodabakhshian, Bahar, Tsang, Michael Y., Luong, Christina, Tsang, Teresa S. M., Abolmaesumi, Purang
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866908834586427392
author Saadat, Armin
Hashemi, Nima
Khodabakhshian, Bahar
Tsang, Michael Y.
Luong, Christina
Tsang, Teresa S. M.
Abolmaesumi, Purang
author_facet Saadat, Armin
Hashemi, Nima
Khodabakhshian, Bahar
Tsang, Michael Y.
Luong, Christina
Tsang, Teresa S. M.
Abolmaesumi, Purang
contents Purpose: Echocardiography with point-of-care ultrasound (POCUS) must support clinical decision-making under tight bedside time and operator-effort constraints. We introduce a personalized data acquisition strategy in which an RL agent, given a partially observed multi-view study, selects the next view to acquire or terminates acquisition to support heart-failure (HF) assessment. Upon termination, a diagnostic model jointly predicts aortic stenosis (AS) severity and left ventricular ejection fraction (LVEF), two key HF biomarkers, and outputs uncertainty, enabling an explicit trade-off between diagnostic performance and acquisition cost. Methods: We model POCUS as a sequential acquisition problem: at each step, a video selector (RL agent) chooses the next view to acquire or terminates acquisition. Upon termination, a shared multi-view transformer performs multi-task inference with two heads, ordinal AS classification, and LVEF regression, and outputs Gaussian predictive distributions yielding ordinal probabilities over AS classes and EF thresholds. These probabilities drive a reward that balances expected diagnostic benefit against acquisition cost, producing patient-specific acquisition pathways. Results: The dataset comprises 12,180 patient-level studies, split into training/validation/test sets (75/15/15). On the 1,820 test studies, our method matches full-study performance while using 32% fewer videos, achieving 77.2% mean balanced accuracy (bACC) across AS severity classification and LVEF estimation, demonstrating robust multi-task performance under acquisition budgets. Conclusion: Patient-tailored, cost-aware acquisition can streamline POCUS workflows while preserving decision quality, producing interpretable scan pathways suited to bedside use. The framework is extensible to additional cardiac endpoints and merits prospective evaluation for clinical integration.
format Preprint
id arxiv_https___arxiv_org_abs_2602_13658
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Optimizing Point-of-Care Ultrasound Video Acquisition for Probabilistic Multi-Task Heart Failure Detection
Saadat, Armin
Hashemi, Nima
Khodabakhshian, Bahar
Tsang, Michael Y.
Luong, Christina
Tsang, Teresa S. M.
Abolmaesumi, Purang
Computer Vision and Pattern Recognition
Purpose: Echocardiography with point-of-care ultrasound (POCUS) must support clinical decision-making under tight bedside time and operator-effort constraints. We introduce a personalized data acquisition strategy in which an RL agent, given a partially observed multi-view study, selects the next view to acquire or terminates acquisition to support heart-failure (HF) assessment. Upon termination, a diagnostic model jointly predicts aortic stenosis (AS) severity and left ventricular ejection fraction (LVEF), two key HF biomarkers, and outputs uncertainty, enabling an explicit trade-off between diagnostic performance and acquisition cost. Methods: We model POCUS as a sequential acquisition problem: at each step, a video selector (RL agent) chooses the next view to acquire or terminates acquisition. Upon termination, a shared multi-view transformer performs multi-task inference with two heads, ordinal AS classification, and LVEF regression, and outputs Gaussian predictive distributions yielding ordinal probabilities over AS classes and EF thresholds. These probabilities drive a reward that balances expected diagnostic benefit against acquisition cost, producing patient-specific acquisition pathways. Results: The dataset comprises 12,180 patient-level studies, split into training/validation/test sets (75/15/15). On the 1,820 test studies, our method matches full-study performance while using 32% fewer videos, achieving 77.2% mean balanced accuracy (bACC) across AS severity classification and LVEF estimation, demonstrating robust multi-task performance under acquisition budgets. Conclusion: Patient-tailored, cost-aware acquisition can streamline POCUS workflows while preserving decision quality, producing interpretable scan pathways suited to bedside use. The framework is extensible to additional cardiac endpoints and merits prospective evaluation for clinical integration.
title Optimizing Point-of-Care Ultrasound Video Acquisition for Probabilistic Multi-Task Heart Failure Detection
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2602.13658