Fluoroscopy-Constrained Magnetic Robot Control via Zernike-Based Field Modeling and Nonlinear MPC

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Chen, Xinhao, Yao, Hongkun, Bhattacharjee, Anuruddha, Raval, Suraj, Mair, Lamar O., Diaz-Mercado, Yancy, Krieger, Axel
Formato: Preprint
Publicado: 2026
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866908837461622784
author Chen, Xinhao
Yao, Hongkun
Bhattacharjee, Anuruddha
Raval, Suraj
Mair, Lamar O.
Diaz-Mercado, Yancy
Krieger, Axel
author_facet Chen, Xinhao
Yao, Hongkun
Bhattacharjee, Anuruddha
Raval, Suraj
Mair, Lamar O.
Diaz-Mercado, Yancy
Krieger, Axel
contents Magnetic actuation enables surgical robots to navigate complex anatomical pathways while reducing tissue trauma and improving surgical precision. However, clinical deployment is limited by the challenges of controlling such systems under fluoroscopic imaging, which provides low frame rate and noisy pose feedback. This paper presents a control framework that remains accurate and stable under such conditions by combining a nonlinear model predictive control (NMPC) framework that directly outputs coil currents, an analytically differentiable magnetic field model based on Zernike polynomials, and a Kalman filter to estimate the robot state. Experimental validation is conducted with two magnetic robots in a 3D-printed fluid workspace and a spine phantom replicating drug delivery in the epidural space. Results show the proposed control method remains highly accurate when feedback is downsampled to 3 Hz with added Gaussian noise (sigma = 2 mm), mimicking clinical fluoroscopy. In the spine phantom experiments, the proposed method successfully executed a drug delivery trajectory with a root mean square (RMS) position error of 1.18 mm while maintaining safe clearance from critical anatomical boundaries.
format Preprint
id arxiv_https___arxiv_org_abs_2602_15357
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Fluoroscopy-Constrained Magnetic Robot Control via Zernike-Based Field Modeling and Nonlinear MPC
Chen, Xinhao
Yao, Hongkun
Bhattacharjee, Anuruddha
Raval, Suraj
Mair, Lamar O.
Diaz-Mercado, Yancy
Krieger, Axel
Robotics
Magnetic actuation enables surgical robots to navigate complex anatomical pathways while reducing tissue trauma and improving surgical precision. However, clinical deployment is limited by the challenges of controlling such systems under fluoroscopic imaging, which provides low frame rate and noisy pose feedback. This paper presents a control framework that remains accurate and stable under such conditions by combining a nonlinear model predictive control (NMPC) framework that directly outputs coil currents, an analytically differentiable magnetic field model based on Zernike polynomials, and a Kalman filter to estimate the robot state. Experimental validation is conducted with two magnetic robots in a 3D-printed fluid workspace and a spine phantom replicating drug delivery in the epidural space. Results show the proposed control method remains highly accurate when feedback is downsampled to 3 Hz with added Gaussian noise (sigma = 2 mm), mimicking clinical fluoroscopy. In the spine phantom experiments, the proposed method successfully executed a drug delivery trajectory with a root mean square (RMS) position error of 1.18 mm while maintaining safe clearance from critical anatomical boundaries.
title Fluoroscopy-Constrained Magnetic Robot Control via Zernike-Based Field Modeling and Nonlinear MPC
topic Robotics
url https://arxiv.org/abs/2602.15357