Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Pinson, Maxime, André, Adélie, Boursier, Yannick, Dupont, Mathieu, Martel, Marie-Laure Gallin, Garnier, Alicia, Hoarau, Christophe, Kavrigin, Pavel, Maneval, Daniel, Morel, Christian, Muraz, Jean-François, Pullia, Marco, Savazzi, Simone, Marcatili, Sara
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910028091359232
author Pinson, Maxime
André, Adélie
Boursier, Yannick
Dupont, Mathieu
Martel, Marie-Laure Gallin
Garnier, Alicia
Hoarau, Christophe
Kavrigin, Pavel
Maneval, Daniel
Morel, Christian
Muraz, Jean-François
Pullia, Marco
Savazzi, Simone
Marcatili, Sara
author_facet Pinson, Maxime
André, Adélie
Boursier, Yannick
Dupont, Mathieu
Martel, Marie-Laure Gallin
Garnier, Alicia
Hoarau, Christophe
Kavrigin, Pavel
Maneval, Daniel
Morel, Christian
Muraz, Jean-François
Pullia, Marco
Savazzi, Simone
Marcatili, Sara
contents In the context of range monitoring for particle therapy, this study presents the first experimental results obtained with the TIARA detector using carbon-ion beams at the CNAO clinical center in Pavia, Italy. TIARA is based on the Prompt Gamma Timing (PGT) technique, which measures the time of flight (TOF) between incident ions and prompt gamma rays (PGs) emitted during nuclear interactions in the target. While the TIARA prototype has previously been validated with protons, carbons present a more challenging scenario due to their higher linear energy transfer, nuclear fragmentation products, and the continuous beam time structure of synchrotron accelerators. Experiments were performed by irradiating PMMA targets of different thicknesses with 200 MeV/u carbon beams. A coincidence time resolution of 279$\pm$35 ps FWHM was achieved, outperforming results previously obtained with protons at the same facility. A range accuracy of 4.74$\pm$0.36 mm at a 2$σ$ confidence level was measured at clinical intensity, when considering 5600 detected PGs, corresponding to the grouping of four irradiation spots of 2.4$\cdot$10$^6$ ions each. Overall, the results demonstrate that PGT-based range monitoring remains viable for carbon-ion beams, although increased background from secondary protons indicates that detector configuration adaptations are required.
format Preprint
id arxiv_https___arxiv_org_abs_2602_18318
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector
Pinson, Maxime
André, Adélie
Boursier, Yannick
Dupont, Mathieu
Martel, Marie-Laure Gallin
Garnier, Alicia
Hoarau, Christophe
Kavrigin, Pavel
Maneval, Daniel
Morel, Christian
Muraz, Jean-François
Pullia, Marco
Savazzi, Simone
Marcatili, Sara
Medical Physics
Instrumentation and Detectors
In the context of range monitoring for particle therapy, this study presents the first experimental results obtained with the TIARA detector using carbon-ion beams at the CNAO clinical center in Pavia, Italy. TIARA is based on the Prompt Gamma Timing (PGT) technique, which measures the time of flight (TOF) between incident ions and prompt gamma rays (PGs) emitted during nuclear interactions in the target. While the TIARA prototype has previously been validated with protons, carbons present a more challenging scenario due to their higher linear energy transfer, nuclear fragmentation products, and the continuous beam time structure of synchrotron accelerators. Experiments were performed by irradiating PMMA targets of different thicknesses with 200 MeV/u carbon beams. A coincidence time resolution of 279$\pm$35 ps FWHM was achieved, outperforming results previously obtained with protons at the same facility. A range accuracy of 4.74$\pm$0.36 mm at a 2$σ$ confidence level was measured at clinical intensity, when considering 5600 detected PGs, corresponding to the grouping of four irradiation spots of 2.4$\cdot$10$^6$ ions each. Overall, the results demonstrate that PGT-based range monitoring remains viable for carbon-ion beams, although increased background from secondary protons indicates that detector configuration adaptations are required.
title Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector
topic Medical Physics
Instrumentation and Detectors
url https://arxiv.org/abs/2602.18318