Test-beam results from MiniCACTUS-v2: A depleted monolithic CMOS timing sensor prototype

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Degerli, Y., Aleksan, R., Casanova, R., Gan, Y., Grinstein, S., Guilloux, F., Hanlon, A., Hemperek, T., Meyer, J. P., Pinol, J., Schwemling, P., Vilella, E.
Formato: Preprint
Publicado: 2026
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866918350842494976
author Degerli, Y.
Aleksan, R.
Casanova, R.
Gan, Y.
Grinstein, S.
Guilloux, F.
Hanlon, A.
Hemperek, T.
Meyer, J. P.
Pinol, J.
Schwemling, P.
Vilella, E.
author_facet Degerli, Y.
Aleksan, R.
Casanova, R.
Gan, Y.
Grinstein, S.
Guilloux, F.
Hanlon, A.
Hemperek, T.
Meyer, J. P.
Pinol, J.
Schwemling, P.
Vilella, E.
contents MiniCACTUS-v2 is a monolithic sensor prototype designed in LF 150 nm CMOS process for time tagging of individual Minimum Ionizing Particles with an accuracy better than 100 ps. The sensing element is a deep n-well/p-substrate diode without internal amplification. To minimize detector capacitances, the analog front-ends and the discriminators for each pixel have been implemented outside the pixel, at the column level. After fabrication, the sensors have been thinned to 150 microns, 175 microns and 200 microns and then post-processed for backside biasing. The breakdown voltages measured on these sensors are higher than 500 V, ensuring the complete depletion of the charge collection volume. In this paper, we will focus on the time resolution measurements from a test-beam campaign conducted in July 2025 at SPS-CERN. During this period, several pixels from the 3 different sensor thicknesses have been tested at different bias voltages. The best time resolution measured is 48.88 ps on a 0.5 mm x 0.5 mm pixel from a 175 microns-thick sensor at 500 V, with nominal settings for the on-chip analog front-end and discriminator.
format Preprint
id arxiv_https___arxiv_org_abs_2602_19890
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Test-beam results from MiniCACTUS-v2: A depleted monolithic CMOS timing sensor prototype
Degerli, Y.
Aleksan, R.
Casanova, R.
Gan, Y.
Grinstein, S.
Guilloux, F.
Hanlon, A.
Hemperek, T.
Meyer, J. P.
Pinol, J.
Schwemling, P.
Vilella, E.
Instrumentation and Detectors
High Energy Physics - Experiment
MiniCACTUS-v2 is a monolithic sensor prototype designed in LF 150 nm CMOS process for time tagging of individual Minimum Ionizing Particles with an accuracy better than 100 ps. The sensing element is a deep n-well/p-substrate diode without internal amplification. To minimize detector capacitances, the analog front-ends and the discriminators for each pixel have been implemented outside the pixel, at the column level. After fabrication, the sensors have been thinned to 150 microns, 175 microns and 200 microns and then post-processed for backside biasing. The breakdown voltages measured on these sensors are higher than 500 V, ensuring the complete depletion of the charge collection volume. In this paper, we will focus on the time resolution measurements from a test-beam campaign conducted in July 2025 at SPS-CERN. During this period, several pixels from the 3 different sensor thicknesses have been tested at different bias voltages. The best time resolution measured is 48.88 ps on a 0.5 mm x 0.5 mm pixel from a 175 microns-thick sensor at 500 V, with nominal settings for the on-chip analog front-end and discriminator.
title Test-beam results from MiniCACTUS-v2: A depleted monolithic CMOS timing sensor prototype
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2602.19890