PSF-Med: Measuring and Explaining Paraphrase Sensitivity in Medical Vision Language Models
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , |
|---|---|
| Format: | Preprint |
| Publié: |
2026
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866915932968845312 |
|---|---|
| author | Sadanandan, Binesh Behzadan, Vahid |
| author_facet | Sadanandan, Binesh Behzadan, Vahid |
| contents | Medical Vision Language Models (VLMs) can change their answers when clinicians rephrase the same question, a failure mode that threatens deployment safety. We introduce PSF-Med, a benchmark of 26,850 chest X-ray questions paired with 92,856 meaning-preserving paraphrases across MIMIC-CXR, PadChest, and VinDr-CXR, spanning clinical populations in the US, Spain, and Vietnam. Every paraphrase is validated by an LLM judge using a bidirectional clinical entailment rubric, with 91.6% cross-family agreement. Across nine VLMs, including general-purpose models, we find flip rates from 3% to 37%. However, low flip rate does not imply visual grounding: text-only baselines show that some models stay consistent even when the image is removed, suggesting they rely on language priors. To study mechanisms in one model, we apply GemmaScope 2 Sparse Autoencoders (SAEs) to MedGemma 4B and analyze FlipBank, a curated set of 158 flip cases. We identify a sparse feature at layer 17 that correlates with prompt framing and predicts decision margin shifts. In causal patching, removing this feature's contribution recovers 45% of the yes-minus-no logit margin on average and fully reverses 15% of flips. Acting on this finding, we show that clamping the identified feature at inference reduces flip rates by 31% relative with only a 1.3 percentage-point accuracy cost, while also decreasing text-prior reliance. These results suggest that flip rate alone is not enough; robustness evaluations should test both paraphrase stability and image reliance. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2602_21428 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | PSF-Med: Measuring and Explaining Paraphrase Sensitivity in Medical Vision Language Models Sadanandan, Binesh Behzadan, Vahid Computer Vision and Pattern Recognition Machine Learning Medical Vision Language Models (VLMs) can change their answers when clinicians rephrase the same question, a failure mode that threatens deployment safety. We introduce PSF-Med, a benchmark of 26,850 chest X-ray questions paired with 92,856 meaning-preserving paraphrases across MIMIC-CXR, PadChest, and VinDr-CXR, spanning clinical populations in the US, Spain, and Vietnam. Every paraphrase is validated by an LLM judge using a bidirectional clinical entailment rubric, with 91.6% cross-family agreement. Across nine VLMs, including general-purpose models, we find flip rates from 3% to 37%. However, low flip rate does not imply visual grounding: text-only baselines show that some models stay consistent even when the image is removed, suggesting they rely on language priors. To study mechanisms in one model, we apply GemmaScope 2 Sparse Autoencoders (SAEs) to MedGemma 4B and analyze FlipBank, a curated set of 158 flip cases. We identify a sparse feature at layer 17 that correlates with prompt framing and predicts decision margin shifts. In causal patching, removing this feature's contribution recovers 45% of the yes-minus-no logit margin on average and fully reverses 15% of flips. Acting on this finding, we show that clamping the identified feature at inference reduces flip rates by 31% relative with only a 1.3 percentage-point accuracy cost, while also decreasing text-prior reliance. These results suggest that flip rate alone is not enough; robustness evaluations should test both paraphrase stability and image reliance. |
| title | PSF-Med: Measuring and Explaining Paraphrase Sensitivity in Medical Vision Language Models |
| topic | Computer Vision and Pattern Recognition Machine Learning |
| url | https://arxiv.org/abs/2602.21428 |