Demonstrating Single Photon Counting with Kinetic Inductance Detectors from 3.8 to 25 $μ$m

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Ras-Vinke, Wilbert G., Kouwenhoven, Kevin, Baselmans, Jochem J. A., Karatsu, Kenichi, Thoen, David J., Murugesan, Vignesh, de Visser, Pieter J.
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866910034029445120
author Ras-Vinke, Wilbert G.
Kouwenhoven, Kevin
Baselmans, Jochem J. A.
Karatsu, Kenichi
Thoen, David J.
Murugesan, Vignesh
de Visser, Pieter J.
author_facet Ras-Vinke, Wilbert G.
Kouwenhoven, Kevin
Baselmans, Jochem J. A.
Karatsu, Kenichi
Thoen, David J.
Murugesan, Vignesh
de Visser, Pieter J.
contents One of the primary objectives of modern astronomy is the atmospheric characterization of Earth-like exoplanets at visible and infrared wavelengths. Achieving this goal requires extremely sensitive detectors capable of measuring faint signal of the exoplanet at the single-photon level while maintaining near-zero dark count rates. In the infrared, however, conventional semiconducting detector technologies struggle to meet these stringent requirements. In this work we demonstrate single-photon counting with superconducting Microwave Kinetic Inductance Detectors at the wavelengths 3.8, 8.5, 18.5, and 25 $μ$m and measure resolving powers ($E/δE$) of 9.9, 5.9, 3.2, and 3.3, respectively, with corresponding dark count rates of 4, 8, 34, and 48 mHz. Our membrane-based devices reach phonon-loss limited performance at 3.8 $μ$m, more than doubling the performance attainable with comparable solid-substrate devices. These results showcase the detector technology in the mid-infrared and the intricate measurement setup required for these sensitive detectors. We discuss how the detector design and measurement setup can be further optimized to increase the detector performance in the mid-infrared.
format Preprint
id arxiv_https___arxiv_org_abs_2602_22970
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Demonstrating Single Photon Counting with Kinetic Inductance Detectors from 3.8 to 25 $μ$m
Ras-Vinke, Wilbert G.
Kouwenhoven, Kevin
Baselmans, Jochem J. A.
Karatsu, Kenichi
Thoen, David J.
Murugesan, Vignesh
de Visser, Pieter J.
Instrumentation and Methods for Astrophysics
Superconductivity
Instrumentation and Detectors
One of the primary objectives of modern astronomy is the atmospheric characterization of Earth-like exoplanets at visible and infrared wavelengths. Achieving this goal requires extremely sensitive detectors capable of measuring faint signal of the exoplanet at the single-photon level while maintaining near-zero dark count rates. In the infrared, however, conventional semiconducting detector technologies struggle to meet these stringent requirements. In this work we demonstrate single-photon counting with superconducting Microwave Kinetic Inductance Detectors at the wavelengths 3.8, 8.5, 18.5, and 25 $μ$m and measure resolving powers ($E/δE$) of 9.9, 5.9, 3.2, and 3.3, respectively, with corresponding dark count rates of 4, 8, 34, and 48 mHz. Our membrane-based devices reach phonon-loss limited performance at 3.8 $μ$m, more than doubling the performance attainable with comparable solid-substrate devices. These results showcase the detector technology in the mid-infrared and the intricate measurement setup required for these sensitive detectors. We discuss how the detector design and measurement setup can be further optimized to increase the detector performance in the mid-infrared.
title Demonstrating Single Photon Counting with Kinetic Inductance Detectors from 3.8 to 25 $μ$m
topic Instrumentation and Methods for Astrophysics
Superconductivity
Instrumentation and Detectors
url https://arxiv.org/abs/2602.22970