Precise Measurement and Control of Radon Progeny on Detector Surfaces

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Luo, C. B. Z., Guo, C., Xiang, L. P., Niu, Y. H., Mo, F. G., Liu, J. C., Zhang, Y. P., Yang, C. G.
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866910036561756160
author Luo, C. B. Z.
Guo, C.
Xiang, L. P.
Niu, Y. H.
Mo, F. G.
Liu, J. C.
Zhang, Y. P.
Yang, C. G.
author_facet Luo, C. B. Z.
Guo, C.
Xiang, L. P.
Niu, Y. H.
Mo, F. G.
Liu, J. C.
Zhang, Y. P.
Yang, C. G.
contents In low-background particle physics experiments, surface deposition of radon progeny presents a significant background challenge. To characterize this contamination, a high-sensitivity surface $α$-activity measurement system was developed, which employs a 3$\times$3 Si-PIN array operating in vacuum to perform $α$-spectroscopy on samples. The system was calibrated using Poly(Methyl MethAcrylate) (PMMA) plates exposed to a controlled high-radon atmosphere, achieving an energy resolution of 2.09 \% for 5.30~MeV $α$ particles and a one-day measurement sensitivity of 1.27~$μ$Bq/cm$^2$ for $^{210}$Po surface activity. Using this system and a self-built high radon concentration chamber, the deposition behavior of radon progeny on PMMA surfaces was investigated. Results indicate a non-monotonic dependence on exposure time, a significant enhancement of deposition with increasing negative surface electrostatic potential, and a strong modulation by ambient humidity. This paper details the apparatus design, calibration, and experimental study of radon progeny deposition dynamics on PMMA surfaces.
format Preprint
id arxiv_https___arxiv_org_abs_2603_00647
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Precise Measurement and Control of Radon Progeny on Detector Surfaces
Luo, C. B. Z.
Guo, C.
Xiang, L. P.
Niu, Y. H.
Mo, F. G.
Liu, J. C.
Zhang, Y. P.
Yang, C. G.
Instrumentation and Detectors
High Energy Physics - Experiment
In low-background particle physics experiments, surface deposition of radon progeny presents a significant background challenge. To characterize this contamination, a high-sensitivity surface $α$-activity measurement system was developed, which employs a 3$\times$3 Si-PIN array operating in vacuum to perform $α$-spectroscopy on samples. The system was calibrated using Poly(Methyl MethAcrylate) (PMMA) plates exposed to a controlled high-radon atmosphere, achieving an energy resolution of 2.09 \% for 5.30~MeV $α$ particles and a one-day measurement sensitivity of 1.27~$μ$Bq/cm$^2$ for $^{210}$Po surface activity. Using this system and a self-built high radon concentration chamber, the deposition behavior of radon progeny on PMMA surfaces was investigated. Results indicate a non-monotonic dependence on exposure time, a significant enhancement of deposition with increasing negative surface electrostatic potential, and a strong modulation by ambient humidity. This paper details the apparatus design, calibration, and experimental study of radon progeny deposition dynamics on PMMA surfaces.
title Precise Measurement and Control of Radon Progeny on Detector Surfaces
topic Instrumentation and Detectors
High Energy Physics - Experiment
url https://arxiv.org/abs/2603.00647