ConVibNet: Needle Detection during Continuous Insertion via Frequency-Inspired Features

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Guo, Jiamei, Duan, Zhehao, Neiiendam, Maria, Huang, Dianye, Navab, Nassir, Jiang, Zhongliang
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908994780528640
author Guo, Jiamei
Duan, Zhehao
Neiiendam, Maria
Huang, Dianye
Navab, Nassir
Jiang, Zhongliang
author_facet Guo, Jiamei
Duan, Zhehao
Neiiendam, Maria
Huang, Dianye
Navab, Nassir
Jiang, Zhongliang
contents Purpose: Ultrasound-guided needle interventions are widely used in clinical practice, but their success critically depends on accurate needle placement, which is frequently hindered by the poor and intermittent visibility of needles in ultrasound images. Existing approaches remain limited by artifacts, occlusions, and low contrast, and often fail to support real-time continuous insertion. To overcome these challenges, this study introduces a robust real-time framework for continuous needle detection. Methods: We present ConVibNet, an extension of VibNet for detecting needles with significantly reduced visibility, addressing real-time, continuous needle tracking during insertion. ConVibNet leverages temporal dependencies across successive ultrasound frames to enable continuous estimation of both needle tip position and shaft angle in dynamic scenarios. To strengthen temporal awareness of needle-tip motion, we introduce a novel intersection-and-difference loss that explicitly leverages motion correlations across consecutive frames. In addition, we curated a dedicated dataset for model development and evaluation. Results: The performance of the proposed ConVibNet model was evaluated on our dataset, demonstrating superior accuracy compared to the baseline VibNet and UNet-LSTM models. Specifically, ConVibNet achieved a tip error of 2.80+-2.42 mm and an angle error of 1.69+-2.00 deg. These results represent a 0.75 mm improvement in tip localization accuracy over the best-performing baseline, while preserving real-time inference capability. Conclusion: ConVibNet advances real-time needle detection in ultrasound-guided interventions by integrating temporal correlation modeling with a novel intersection-and-difference loss, thereby improving accuracy and robustness and demonstrating high potential for integration into autonomous insertion systems.
format Preprint
id arxiv_https___arxiv_org_abs_2603_01147
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle ConVibNet: Needle Detection during Continuous Insertion via Frequency-Inspired Features
Guo, Jiamei
Duan, Zhehao
Neiiendam, Maria
Huang, Dianye
Navab, Nassir
Jiang, Zhongliang
Computer Vision and Pattern Recognition
Purpose: Ultrasound-guided needle interventions are widely used in clinical practice, but their success critically depends on accurate needle placement, which is frequently hindered by the poor and intermittent visibility of needles in ultrasound images. Existing approaches remain limited by artifacts, occlusions, and low contrast, and often fail to support real-time continuous insertion. To overcome these challenges, this study introduces a robust real-time framework for continuous needle detection. Methods: We present ConVibNet, an extension of VibNet for detecting needles with significantly reduced visibility, addressing real-time, continuous needle tracking during insertion. ConVibNet leverages temporal dependencies across successive ultrasound frames to enable continuous estimation of both needle tip position and shaft angle in dynamic scenarios. To strengthen temporal awareness of needle-tip motion, we introduce a novel intersection-and-difference loss that explicitly leverages motion correlations across consecutive frames. In addition, we curated a dedicated dataset for model development and evaluation. Results: The performance of the proposed ConVibNet model was evaluated on our dataset, demonstrating superior accuracy compared to the baseline VibNet and UNet-LSTM models. Specifically, ConVibNet achieved a tip error of 2.80+-2.42 mm and an angle error of 1.69+-2.00 deg. These results represent a 0.75 mm improvement in tip localization accuracy over the best-performing baseline, while preserving real-time inference capability. Conclusion: ConVibNet advances real-time needle detection in ultrasound-guided interventions by integrating temporal correlation modeling with a novel intersection-and-difference loss, thereby improving accuracy and robustness and demonstrating high potential for integration into autonomous insertion systems.
title ConVibNet: Needle Detection during Continuous Insertion via Frequency-Inspired Features
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2603.01147