contents Broadband seismometers are widely used in global observation networks deployed for geophysics research. Recently, the calibration of their sensitivity has become an important factor for ensuring observation accuracy. One of the limiting factors of calibration uncertainty is the temperature dependence of the sensitivity because seismometers operate in a wide range of temperatures. However, systems that accurately measure the temperature coefficient in seismometers have not been established. Herein, we develop such a system using a triaxial vibration exciter combined with a thermostatic chamber. Using this system, we calibrated several broadband seismometers (Trillium Compact, Trillium Horizon 360, and CMG-3T) at various temperatures, ranging from $-15 ^\circ$C to $+45 ^\circ$C. We found that the temperature coefficient was $(0.11\pm0.01)$ %/$^\circ$C, which can be attributed to the internal magnet of the seismometers. The variation of the phase delay corresponded to a change of less than 2 ms in output time delay. Additionally, we found that the relative frequency response below 1 Hz was stable against temperature variations. These values are useful for evaluating the measurement accuracy of seismometer observation networks.
format Preprint
id arxiv_https___arxiv_org_abs_2603_01159
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Temperature dependence of broadband seismometer sensitivity
Shimoda, Tomofumi
Kokuyama, Wataru
Nozato, Hideaki
Geophysics
Broadband seismometers are widely used in global observation networks deployed for geophysics research. Recently, the calibration of their sensitivity has become an important factor for ensuring observation accuracy. One of the limiting factors of calibration uncertainty is the temperature dependence of the sensitivity because seismometers operate in a wide range of temperatures. However, systems that accurately measure the temperature coefficient in seismometers have not been established. Herein, we develop such a system using a triaxial vibration exciter combined with a thermostatic chamber. Using this system, we calibrated several broadband seismometers (Trillium Compact, Trillium Horizon 360, and CMG-3T) at various temperatures, ranging from $-15 ^\circ$C to $+45 ^\circ$C. We found that the temperature coefficient was $(0.11\pm0.01)$ %/$^\circ$C, which can be attributed to the internal magnet of the seismometers. The variation of the phase delay corresponded to a change of less than 2 ms in output time delay. Additionally, we found that the relative frequency response below 1 Hz was stable against temperature variations. These values are useful for evaluating the measurement accuracy of seismometer observation networks.
title Temperature dependence of broadband seismometer sensitivity
topic Geophysics
url https://arxiv.org/abs/2603.01159