Digital Twin-Based Cooling System Optimization for Data Center

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Jadhav, Shrenik, Liu, Zheng
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866912950465331200
author Jadhav, Shrenik
Liu, Zheng
author_facet Jadhav, Shrenik
Liu, Zheng
contents Data center cooling systems consume significant auxiliary energy, yet optimization studies rarely quantify the gap between theoretically optimal and operationally deployable control strategies. This paper develops a digital twin of the liquid cooling infrastructure at the Frontier exascale supercomputer, in which a hot-temperature water system comprises three parallel subloops, each serving dedicated coolant distribution unit clusters through plate heat exchangers and variable-speed pumps. The surrogate model is built based on Modelica and validated through one full calendar year of 10-minute operational data following ASHRAE Guideline 14. The model achieves a subloop coefficient of variation of the root mean square error below 2.7% and a normalized mean bias error within 2.5%. Using this validated surrogate model, a layered optimization framework evaluates three progressively constrained strategies: an analytical flow-only optimization achieves 20.4% total energy saving, unconstrained joint optimization of flow rate and supply temperature demonstrates 30.1% total energy saving, and ramp-constrained optimization of flow rate and supply temperature, enforcing actuator rate limits, can reach total energy saving of 27.8%. The analysis reveals that the baseline system operates at 2.9 times the minimum thermally safe flow rate, and the co-optimizing supply temperature with flow rate nearly doubles the savings achievable by flow reduction alone.
format Preprint
id arxiv_https___arxiv_org_abs_2603_01198
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Digital Twin-Based Cooling System Optimization for Data Center
Jadhav, Shrenik
Liu, Zheng
Systems and Control
Applications
Data center cooling systems consume significant auxiliary energy, yet optimization studies rarely quantify the gap between theoretically optimal and operationally deployable control strategies. This paper develops a digital twin of the liquid cooling infrastructure at the Frontier exascale supercomputer, in which a hot-temperature water system comprises three parallel subloops, each serving dedicated coolant distribution unit clusters through plate heat exchangers and variable-speed pumps. The surrogate model is built based on Modelica and validated through one full calendar year of 10-minute operational data following ASHRAE Guideline 14. The model achieves a subloop coefficient of variation of the root mean square error below 2.7% and a normalized mean bias error within 2.5%. Using this validated surrogate model, a layered optimization framework evaluates three progressively constrained strategies: an analytical flow-only optimization achieves 20.4% total energy saving, unconstrained joint optimization of flow rate and supply temperature demonstrates 30.1% total energy saving, and ramp-constrained optimization of flow rate and supply temperature, enforcing actuator rate limits, can reach total energy saving of 27.8%. The analysis reveals that the baseline system operates at 2.9 times the minimum thermally safe flow rate, and the co-optimizing supply temperature with flow rate nearly doubles the savings achievable by flow reduction alone.
title Digital Twin-Based Cooling System Optimization for Data Center
topic Systems and Control
Applications
url https://arxiv.org/abs/2603.01198