Improvement and assessment of the radiopurity of Micromegas readout planes

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Castel, Juan, Cebrian, Susana, Dafni, Theopisti, Diez-Ibanez, David, Ezquerro, Alvaro, Garcia, Juan Antonio, Gomez, Hector, Irastorza, Igor G., Luzon, Gloria, Margalejo, Cristina, Mirallas, Hector, Obis, Luis, de Oliveira, Rui, de Solorzano, Alfonso Ortiz, Perez, Oscar, Porron, Jorge, Puyuelo, Maria J., Quintana, Ana, Rodriguez, Maria, Segui, Laura
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911483125825536
author Castel, Juan
Cebrian, Susana
Dafni, Theopisti
Diez-Ibanez, David
Ezquerro, Alvaro
Garcia, Juan Antonio
Gomez, Hector
Irastorza, Igor G.
Luzon, Gloria
Margalejo, Cristina
Mirallas, Hector
Obis, Luis
de Oliveira, Rui
de Solorzano, Alfonso Ortiz
Perez, Oscar
Porron, Jorge
Puyuelo, Maria J.
Quintana, Ana
Rodriguez, Maria
Segui, Laura
author_facet Castel, Juan
Cebrian, Susana
Dafni, Theopisti
Diez-Ibanez, David
Ezquerro, Alvaro
Garcia, Juan Antonio
Gomez, Hector
Irastorza, Igor G.
Luzon, Gloria
Margalejo, Cristina
Mirallas, Hector
Obis, Luis
de Oliveira, Rui
de Solorzano, Alfonso Ortiz
Perez, Oscar
Porron, Jorge
Puyuelo, Maria J.
Quintana, Ana
Rodriguez, Maria
Segui, Laura
contents Micromesh Gas Structures (Micromegas) as readout of gaseous Time Projection Chambers (TPCs) are being considered in experiments investigating rare phenomena, like the nuclear double beta decay, solar axion detection and low-mass dark matter interactions, due to their good performance on spatial and energy resolution and operation stability. In addition, as they are potentially made mainly of radiopure materials like copper and kapton, they are appropriate for ultra-low background conditions. After a promising first study of the radiopurity of Micromegas readout planes, here results after dedicated development at CERN obtained from new radioassays, performed at the Canfranc Underground Laboratory combining different techniques, are presented. Activity of the isotopes in the lower parts of the 238U and 232Th natural chains has been constrained by analyzing the BiPo sequences using the BiPo-3 detector to be <0.064 and <0.016 muBq/cm2 respectively, while a lowest 40K content of 0.102+-0.030 muBq/cm2 has been determined by gamma spectroscopy using a HPGe detector; the latter value implies a reduction of a factor 34 with respect to the 40K activity quantified in the first analyzed sample. These results confirm the suitability of the use of Micromegas as extremely radiopure readouts for rare event searches.
format Preprint
id arxiv_https___arxiv_org_abs_2603_03274
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Improvement and assessment of the radiopurity of Micromegas readout planes
Castel, Juan
Cebrian, Susana
Dafni, Theopisti
Diez-Ibanez, David
Ezquerro, Alvaro
Garcia, Juan Antonio
Gomez, Hector
Irastorza, Igor G.
Luzon, Gloria
Margalejo, Cristina
Mirallas, Hector
Obis, Luis
de Oliveira, Rui
de Solorzano, Alfonso Ortiz
Perez, Oscar
Porron, Jorge
Puyuelo, Maria J.
Quintana, Ana
Rodriguez, Maria
Segui, Laura
Instrumentation and Detectors
High Energy Physics - Experiment
Nuclear Experiment
Micromesh Gas Structures (Micromegas) as readout of gaseous Time Projection Chambers (TPCs) are being considered in experiments investigating rare phenomena, like the nuclear double beta decay, solar axion detection and low-mass dark matter interactions, due to their good performance on spatial and energy resolution and operation stability. In addition, as they are potentially made mainly of radiopure materials like copper and kapton, they are appropriate for ultra-low background conditions. After a promising first study of the radiopurity of Micromegas readout planes, here results after dedicated development at CERN obtained from new radioassays, performed at the Canfranc Underground Laboratory combining different techniques, are presented. Activity of the isotopes in the lower parts of the 238U and 232Th natural chains has been constrained by analyzing the BiPo sequences using the BiPo-3 detector to be <0.064 and <0.016 muBq/cm2 respectively, while a lowest 40K content of 0.102+-0.030 muBq/cm2 has been determined by gamma spectroscopy using a HPGe detector; the latter value implies a reduction of a factor 34 with respect to the 40K activity quantified in the first analyzed sample. These results confirm the suitability of the use of Micromegas as extremely radiopure readouts for rare event searches.
title Improvement and assessment of the radiopurity of Micromegas readout planes
topic Instrumentation and Detectors
High Energy Physics - Experiment
Nuclear Experiment
url https://arxiv.org/abs/2603.03274