contents Radiation detectors deployed as part of a large urban network or for homeland security monitoring must maintain reliable energy calibration even when subjected to substantial variations in temperature and ambient background radiation. Traditional calibration methods often rely on power-intensive temperature stabilization or peak-locking algorithms that are susceptible to environmental changes. This publication presents a novel software-based calibration method that eliminates the need for active temperature control by utilizing full-spectrum analysis. The method continuously updates the calibration parameters by fitting the spectral data with a series of background radiation contributions (K, U, Th series, radon progeny and cosmics) combined with a Monte-Carlo-based physical detector model that incorporates light yield non-proportionality and photomultiplier tube saturation. Performance was validated using simulated data, measurements in an environmental chamber across a wide temperature range (-25C to +50C), and data from a multi-day outdoor field deployment. Results demonstrate that the method successfully maintains stable energy calibration despite significant ambient temperature variations and precipitation events. The technique effectively decouples instrumental drift from spectral changes caused by environmental background fluctuations. This approach provides a robust, automated, and low-power alternative to conventional calibration techniques, enabling the practical deployment of large-scale, unattended networked detector systems.
format Preprint
id arxiv_https___arxiv_org_abs_2603_03461
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Automatic calibration of gamma-ray detectors deployed in uncontrolled environments
Salathe, Marco
Abgrall, Nicolas
Bandstra, Mark S.
Joshi, Tenzing H. Y.
Quiter, Brian J.
Cooper, Reynold J.
Instrumentation and Detectors
Nuclear Experiment
Radiation detectors deployed as part of a large urban network or for homeland security monitoring must maintain reliable energy calibration even when subjected to substantial variations in temperature and ambient background radiation. Traditional calibration methods often rely on power-intensive temperature stabilization or peak-locking algorithms that are susceptible to environmental changes. This publication presents a novel software-based calibration method that eliminates the need for active temperature control by utilizing full-spectrum analysis. The method continuously updates the calibration parameters by fitting the spectral data with a series of background radiation contributions (K, U, Th series, radon progeny and cosmics) combined with a Monte-Carlo-based physical detector model that incorporates light yield non-proportionality and photomultiplier tube saturation. Performance was validated using simulated data, measurements in an environmental chamber across a wide temperature range (-25C to +50C), and data from a multi-day outdoor field deployment. Results demonstrate that the method successfully maintains stable energy calibration despite significant ambient temperature variations and precipitation events. The technique effectively decouples instrumental drift from spectral changes caused by environmental background fluctuations. This approach provides a robust, automated, and low-power alternative to conventional calibration techniques, enabling the practical deployment of large-scale, unattended networked detector systems.
title Automatic calibration of gamma-ray detectors deployed in uncontrolled environments
topic Instrumentation and Detectors
Nuclear Experiment
url https://arxiv.org/abs/2603.03461