Continuous Ventricular Volumetric Quantification in Patients with Arrhythmias using Real-Time 3D CMR-MOTUS

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Olausson, Thomas E., Terpstra, Maarten L., Ahmad, Rizwan, Versteeg, Edwin, Beijst, Casper, Han, Yuchi, Guglielmo, Marco, Velthuis, Birgitta K., Berg, Cornelis van den, Sbrizzi, Alessandro
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866910041055952896
author Olausson, Thomas E.
Terpstra, Maarten L.
Ahmad, Rizwan
Versteeg, Edwin
Beijst, Casper
Han, Yuchi
Guglielmo, Marco
Velthuis, Birgitta K.
Berg, Cornelis van den
Sbrizzi, Alessandro
author_facet Olausson, Thomas E.
Terpstra, Maarten L.
Ahmad, Rizwan
Versteeg, Edwin
Beijst, Casper
Han, Yuchi
Guglielmo, Marco
Velthuis, Birgitta K.
Berg, Cornelis van den
Sbrizzi, Alessandro
contents Conventional cardiovascular magnetic resonance (CMR) cine imaging relies on binning multiple heartbeats into a single cardiac cycle, which fails in arrhythmic patients where beat-to-beat variability causes motion artifacts and loss of functional information. Real-time 2D imaging captures individual beats but lacks volumetric coverage for mapping arrhythmic cardiac dynamics. We present a 3D real-time motion-field reconstruction method enabling continuous volumetric assessment in patients with premature ventricular contractions (PVCs) using a free-running CMR protocol. CMR-MOTUS was extended to jointly reconstruct real-time 3D motion fields and a motion-corrected reference image from continuous, ungated, non-breath-held data acquired with a variable-density Cartesian OPRA trajectory. Beat-to-beat ejection fraction (EF) was computed by propagating a single segmentation through all frames using the reconstructed motion fields. The method was validated on a cardiac motion phantom and tested in four healthy volunteers and four PVC patients. Phantom EF closely matched ground truth (22.1 +/- 0.6 percent vs. 21.9 percent). In healthy volunteers, EF values agreed with 2D references and showed narrow distributions reflecting physiological consistency. In PVC patients, EF distributions were bimodal, with the lower mode corresponding to PVC beats with markedly reduced EF. ECG confirmed alignment between EF irregularities and PVC episodes. These results show that 3D real-time motion-field reconstruction enables continuous beat-to-beat volumetric quantification in arrhythmia, revealing functional heterogeneity that conventional binning obscures. The bimodal EF distributions capture the true hemodynamic impact of PVCs and may provide clinically relevant metrics for monitoring and treatment evaluation.
format Preprint
id arxiv_https___arxiv_org_abs_2603_04233
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Continuous Ventricular Volumetric Quantification in Patients with Arrhythmias using Real-Time 3D CMR-MOTUS
Olausson, Thomas E.
Terpstra, Maarten L.
Ahmad, Rizwan
Versteeg, Edwin
Beijst, Casper
Han, Yuchi
Guglielmo, Marco
Velthuis, Birgitta K.
Berg, Cornelis van den
Sbrizzi, Alessandro
Medical Physics
Conventional cardiovascular magnetic resonance (CMR) cine imaging relies on binning multiple heartbeats into a single cardiac cycle, which fails in arrhythmic patients where beat-to-beat variability causes motion artifacts and loss of functional information. Real-time 2D imaging captures individual beats but lacks volumetric coverage for mapping arrhythmic cardiac dynamics. We present a 3D real-time motion-field reconstruction method enabling continuous volumetric assessment in patients with premature ventricular contractions (PVCs) using a free-running CMR protocol. CMR-MOTUS was extended to jointly reconstruct real-time 3D motion fields and a motion-corrected reference image from continuous, ungated, non-breath-held data acquired with a variable-density Cartesian OPRA trajectory. Beat-to-beat ejection fraction (EF) was computed by propagating a single segmentation through all frames using the reconstructed motion fields. The method was validated on a cardiac motion phantom and tested in four healthy volunteers and four PVC patients. Phantom EF closely matched ground truth (22.1 +/- 0.6 percent vs. 21.9 percent). In healthy volunteers, EF values agreed with 2D references and showed narrow distributions reflecting physiological consistency. In PVC patients, EF distributions were bimodal, with the lower mode corresponding to PVC beats with markedly reduced EF. ECG confirmed alignment between EF irregularities and PVC episodes. These results show that 3D real-time motion-field reconstruction enables continuous beat-to-beat volumetric quantification in arrhythmia, revealing functional heterogeneity that conventional binning obscures. The bimodal EF distributions capture the true hemodynamic impact of PVCs and may provide clinically relevant metrics for monitoring and treatment evaluation.
title Continuous Ventricular Volumetric Quantification in Patients with Arrhythmias using Real-Time 3D CMR-MOTUS
topic Medical Physics
url https://arxiv.org/abs/2603.04233