Cubic magneto-optic Kerr effect in Co(111) thin films

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Gaerner, Maik, Silber, Robin, Schäffer, Malte, Hamrle, Jaroslav, Ehrmann, Andrea, Wortmann, Martin, Kuschel, Timo
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866915837728784384
author Gaerner, Maik
Silber, Robin
Schäffer, Malte
Hamrle, Jaroslav
Ehrmann, Andrea
Wortmann, Martin
Kuschel, Timo
author_facet Gaerner, Maik
Silber, Robin
Schäffer, Malte
Hamrle, Jaroslav
Ehrmann, Andrea
Wortmann, Martin
Kuschel, Timo
contents The magneto-optic Kerr effect (MOKE) is often applied as a tool for the magnetic characterization of thin films. Here, the change in polarization upon reflection from the magnetized sample is mainly regarded as being linearly proportional to the magnetization $\mathbf{M}$ (LinMOKE). MOKE contributions of second order in $\mathbf{M}$, also known as quadratic MOKE (QMOKE), which are proportional to $\mathbf{M}^2$, have also been studied in the past and used in thin film characterization. Recently, we reported on a systematic investigation of third-order MOKE contributions, named cubic MOKE (CMOKE) in Ni(111) thin films. This CMOKE manifests itself as an anisotropic contribution to the MOKE signal (with regard to the crystallographic orientation) measured in longitudinal or transversal configuration in full magnetic saturation. While LinMOKE (odd in $\mathbf{M}$) and QMOKE (even in $\mathbf{M}$) can easily be separated by methods based on magnetization parity, this no longer holds true for LinMOKE and CMOKE (odd in $\mathbf{M}$). It is therefore crucial to be aware of CMOKE contributions in order to correctly interpret MOKE data. Here, we report on the observation of CMOKE in thin film heterostructures with structurally twinned and untwinned Co(111) layers, demonstrating that a large CMOKE is not only present in Ni thin films. Additionally, we show that the observed anisotropic contributions cannot stem from LinMOKE by analyzing their dependence on the angle of incidence (AoI) of light. While the QMOKE is almost vanishing in Co(111) using light with wavelengths of 635\,nm and 406\,nm, the CMOKE contributions reach up to about 30\% of the LinMOKE contribution at an AoI of 45 degrees and become even more dominant towards normal AoI, which emphasizes the importance of higher-order MOKE effects in magneto-optic experiments.
format Preprint
id arxiv_https___arxiv_org_abs_2603_05348
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Cubic magneto-optic Kerr effect in Co(111) thin films
Gaerner, Maik
Silber, Robin
Schäffer, Malte
Hamrle, Jaroslav
Ehrmann, Andrea
Wortmann, Martin
Kuschel, Timo
Optics
The magneto-optic Kerr effect (MOKE) is often applied as a tool for the magnetic characterization of thin films. Here, the change in polarization upon reflection from the magnetized sample is mainly regarded as being linearly proportional to the magnetization $\mathbf{M}$ (LinMOKE). MOKE contributions of second order in $\mathbf{M}$, also known as quadratic MOKE (QMOKE), which are proportional to $\mathbf{M}^2$, have also been studied in the past and used in thin film characterization. Recently, we reported on a systematic investigation of third-order MOKE contributions, named cubic MOKE (CMOKE) in Ni(111) thin films. This CMOKE manifests itself as an anisotropic contribution to the MOKE signal (with regard to the crystallographic orientation) measured in longitudinal or transversal configuration in full magnetic saturation. While LinMOKE (odd in $\mathbf{M}$) and QMOKE (even in $\mathbf{M}$) can easily be separated by methods based on magnetization parity, this no longer holds true for LinMOKE and CMOKE (odd in $\mathbf{M}$). It is therefore crucial to be aware of CMOKE contributions in order to correctly interpret MOKE data. Here, we report on the observation of CMOKE in thin film heterostructures with structurally twinned and untwinned Co(111) layers, demonstrating that a large CMOKE is not only present in Ni thin films. Additionally, we show that the observed anisotropic contributions cannot stem from LinMOKE by analyzing their dependence on the angle of incidence (AoI) of light. While the QMOKE is almost vanishing in Co(111) using light with wavelengths of 635\,nm and 406\,nm, the CMOKE contributions reach up to about 30\% of the LinMOKE contribution at an AoI of 45 degrees and become even more dominant towards normal AoI, which emphasizes the importance of higher-order MOKE effects in magneto-optic experiments.
title Cubic magneto-optic Kerr effect in Co(111) thin films
topic Optics
url https://arxiv.org/abs/2603.05348