Sparse probabilistic evaluation for treatment planning: a feasibility study in IMPT head & neck patients

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: de Jong, Jenneke I., Habraken, Steven J. M., Fredriksson, Albin, Sundström, Johan, Engwall, Erik, Breedveld, Sebastiaan, Hoogeman, Mischa S.
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866917318540394496
author de Jong, Jenneke I.
Habraken, Steven J. M.
Fredriksson, Albin
Sundström, Johan
Engwall, Erik
Breedveld, Sebastiaan
Hoogeman, Mischa S.
author_facet de Jong, Jenneke I.
Habraken, Steven J. M.
Fredriksson, Albin
Sundström, Johan
Engwall, Erik
Breedveld, Sebastiaan
Hoogeman, Mischa S.
contents Probabilistic evaluation improves the trade-off between target coverage and OAR sparing in IMPT but remains computationally demanding. This study proposes sparse probabilistic evaluation (SPE), a computationally efficient approach integrated into a clinical TPS. Clinical plans of 20 IMPT HNC patients treated in 2024 were included. SPE used a predefined setup and range error grid with Monte Carlo computed dose distributions. Two grid settings were evaluated: the maximum error Emax (3$σ$ or 4$σ$) and the number of setup error points nsetup (7, 33, 123). Accuracy and duration of SPE with each grid were evaluated in the calibration group (5 patients). 1000 treatments with normally distributed random ($σ$ = 1 mm) and systematic ($σ$ = 0.92 mm) setup and range ($σ$ = 1.5%) errors were simulated. The dose distribution of the nearest error point in the grid was assigned to each fraction. Probability distributions derived from SPE were compared with those from a reference based on 35,000 Monte Carlo calculations. The found optimal grid (Emax = 3$σ$, nsetup = 33) was applied to the validation group (15 patients). Accuracy of SPE in the calibration group increased significantly as the number of error points increased from 7 (tavg = 2 minutes) to 33 (tavg = 9 minutes), with no further improvement between 33 and 123 (tavg = 27 minutes) error points. Increasing Emax only improved accuracy for values above the 98th percentile. Applying SPE to the validation group resulted in median errors of 0.02 Gy RBE (range:-0.11 to 0.07) for the 10th percentile of the D99.8%, CTV distribution and 0.0 Gy RBE (range:-0.14 to 0.23) for the 95th percentile of the D0.03cc,SpinalCord Core distribution. Sparse probabilistic evaluation achieves sufficient accuracy while requiring clinically acceptable computation times, paving the way for probabilistic evaluation in clinical practice.
format Preprint
id arxiv_https___arxiv_org_abs_2603_06314
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Sparse probabilistic evaluation for treatment planning: a feasibility study in IMPT head & neck patients
de Jong, Jenneke I.
Habraken, Steven J. M.
Fredriksson, Albin
Sundström, Johan
Engwall, Erik
Breedveld, Sebastiaan
Hoogeman, Mischa S.
Medical Physics
Probabilistic evaluation improves the trade-off between target coverage and OAR sparing in IMPT but remains computationally demanding. This study proposes sparse probabilistic evaluation (SPE), a computationally efficient approach integrated into a clinical TPS. Clinical plans of 20 IMPT HNC patients treated in 2024 were included. SPE used a predefined setup and range error grid with Monte Carlo computed dose distributions. Two grid settings were evaluated: the maximum error Emax (3$σ$ or 4$σ$) and the number of setup error points nsetup (7, 33, 123). Accuracy and duration of SPE with each grid were evaluated in the calibration group (5 patients). 1000 treatments with normally distributed random ($σ$ = 1 mm) and systematic ($σ$ = 0.92 mm) setup and range ($σ$ = 1.5%) errors were simulated. The dose distribution of the nearest error point in the grid was assigned to each fraction. Probability distributions derived from SPE were compared with those from a reference based on 35,000 Monte Carlo calculations. The found optimal grid (Emax = 3$σ$, nsetup = 33) was applied to the validation group (15 patients). Accuracy of SPE in the calibration group increased significantly as the number of error points increased from 7 (tavg = 2 minutes) to 33 (tavg = 9 minutes), with no further improvement between 33 and 123 (tavg = 27 minutes) error points. Increasing Emax only improved accuracy for values above the 98th percentile. Applying SPE to the validation group resulted in median errors of 0.02 Gy RBE (range:-0.11 to 0.07) for the 10th percentile of the D99.8%, CTV distribution and 0.0 Gy RBE (range:-0.14 to 0.23) for the 95th percentile of the D0.03cc,SpinalCord Core distribution. Sparse probabilistic evaluation achieves sufficient accuracy while requiring clinically acceptable computation times, paving the way for probabilistic evaluation in clinical practice.
title Sparse probabilistic evaluation for treatment planning: a feasibility study in IMPT head & neck patients
topic Medical Physics
url https://arxiv.org/abs/2603.06314