DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Zhou, Yinchi, Guo, Liang, Xie, Huidong, Du, Yuexi, Wang, Ashley, Xia, Menghua, Yu, Tian, Fazzone-Chettiar, Ramesh, Weyman, Christopher, Spottiswoode, Bruce, Panin, Vladimir, Shi, Kuangyu, Miller, Edward J., Feher, Attila, Sinusas, Albert J., Dvornek, Nicha C., Liu, Chi
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866914379531812864
author Zhou, Yinchi
Guo, Liang
Xie, Huidong
Du, Yuexi
Wang, Ashley
Xia, Menghua
Yu, Tian
Fazzone-Chettiar, Ramesh
Weyman, Christopher
Spottiswoode, Bruce
Panin, Vladimir
Shi, Kuangyu
Miller, Edward J.
Feher, Attila
Sinusas, Albert J.
Dvornek, Nicha C.
Liu, Chi
author_facet Zhou, Yinchi
Guo, Liang
Xie, Huidong
Du, Yuexi
Wang, Ashley
Xia, Menghua
Yu, Tian
Fazzone-Chettiar, Ramesh
Weyman, Christopher
Spottiswoode, Bruce
Panin, Vladimir
Shi, Kuangyu
Miller, Edward J.
Feher, Attila
Sinusas, Albert J.
Dvornek, Nicha C.
Liu, Chi
contents Rb-82 dynamic cardiac PET imaging is widely used for the clinical diagnosis of coronary artery disease (CAD), but its short half-life results in high noise levels that degrade dynamic frame quality and parametric imaging. The lack of paired clean-noisy training data, rapid tracer kinetics, and frame-dependent noise variations further limit the effectiveness of existing deep learning denoising methods. We propose DECADE (A Temporally-Consistent Unsupervised Diffusion model for Enhanced Rb-82 CArdiac PET DEnoising), an unsupervised diffusion framework that generalizes across early- to late-phase dynamic frames. DECADE incorporates temporal consistency during both training and iterative sampling, using noisy frames as guidance to preserve quantitative accuracy. The method was trained and evaluated on datasets acquired from Siemens Vision 450 and Siemens Biograph Vision Quadra scanners. On the Vision 450 dataset, DECADE consistently produced high-quality dynamic and parametric images with reduced noise while preserving myocardial blood flow (MBF) and myocardial flow reserve (MFR). On the Quadra dataset, using 15%-count images as input and full-count images as reference, DECADE outperformed UNet-based and other diffusion models in image quality and K1/MBF quantification. The proposed framework enables effective unsupervised denoising of Rb-82 dynamic cardiac PET without paired training data, supporting clearer visualization while maintaining quantitative integrity.
format Preprint
id arxiv_https___arxiv_org_abs_2603_07759
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising
Zhou, Yinchi
Guo, Liang
Xie, Huidong
Du, Yuexi
Wang, Ashley
Xia, Menghua
Yu, Tian
Fazzone-Chettiar, Ramesh
Weyman, Christopher
Spottiswoode, Bruce
Panin, Vladimir
Shi, Kuangyu
Miller, Edward J.
Feher, Attila
Sinusas, Albert J.
Dvornek, Nicha C.
Liu, Chi
Computer Vision and Pattern Recognition
Artificial Intelligence
Rb-82 dynamic cardiac PET imaging is widely used for the clinical diagnosis of coronary artery disease (CAD), but its short half-life results in high noise levels that degrade dynamic frame quality and parametric imaging. The lack of paired clean-noisy training data, rapid tracer kinetics, and frame-dependent noise variations further limit the effectiveness of existing deep learning denoising methods. We propose DECADE (A Temporally-Consistent Unsupervised Diffusion model for Enhanced Rb-82 CArdiac PET DEnoising), an unsupervised diffusion framework that generalizes across early- to late-phase dynamic frames. DECADE incorporates temporal consistency during both training and iterative sampling, using noisy frames as guidance to preserve quantitative accuracy. The method was trained and evaluated on datasets acquired from Siemens Vision 450 and Siemens Biograph Vision Quadra scanners. On the Vision 450 dataset, DECADE consistently produced high-quality dynamic and parametric images with reduced noise while preserving myocardial blood flow (MBF) and myocardial flow reserve (MFR). On the Quadra dataset, using 15%-count images as input and full-count images as reference, DECADE outperformed UNet-based and other diffusion models in image quality and K1/MBF quantification. The proposed framework enables effective unsupervised denoising of Rb-82 dynamic cardiac PET without paired training data, supporting clearer visualization while maintaining quantitative integrity.
title DECADE: A Temporally-Consistent Unsupervised Diffusion Model for Enhanced Rb-82 Dynamic Cardiac PET Image Denoising
topic Computer Vision and Pattern Recognition
Artificial Intelligence
url https://arxiv.org/abs/2603.07759