Bayesian Transformer for Probabilistic Load Forecasting in Smart Grids
Fuente:
arXiv
Gespeichert in:
| Hauptverfasser: | , |
|---|---|
| Format: | Preprint |
| Veröffentlicht: |
2026
|
| Schlagworte: | |
| Online-Zugang: | |
| Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
| _version_ | 1866912954476134400 |
|---|---|
| author | Debnath, Sajib Mia, Md. Uzzal |
| author_facet | Debnath, Sajib Mia, Md. Uzzal |
| contents | The reliable operation of modern power grids requires probabilistic load forecasts with well-calibrated uncertainty estimates. However, existing deep learning models produce overconfident point predictions that fail catastrophically under extreme weather distributional shifts. This study proposes a Bayesian Transformer (BT) framework that integrates three complementary uncertainty mechanisms into a PatchTST backbone: Monte Carlo Dropout for epistemic parameter uncertainty, variational feed-forward layers with log-uniform weight priors, and stochastic attention with learnable Gaussian noise perturbations on pre-softmax logits, representing, to the best of our knowledge, the first application of Bayesian attention to probabilistic load forecasting. A seven-level multi-quantile pinball-loss prediction head and post-training isotonic regression calibration produce sharp, near-nominally covered prediction intervals. Evaluation of five grid datasets (PJM, ERCOT, ENTSO-E Germany, France, and Great Britain) augmented with NOAA covariates across 24, 48, and 168-hour horizons demonstrates state-of-the-art performance. On the primary benchmark (PJM, H=24h), BT achieves a CRPS of 0.0289, improving 7.4% over Deep Ensembles and 29.9% over the deterministic LSTM, with 90.4% PICP at the 90% nominal level and the narrowest prediction intervals (4,960 MW) among all probabilistic baselines. During heat-wave and cold snap events, BT maintained 89.6% and 90.1% PICP respectively, versus 64.7% and 67.2% for the deterministic LSTM, confirming that Bayesian epistemic uncertainty naturally widens intervals for out-of-distribution inputs. Calibration remained stable across all horizons (89.8-90.4% PICP), while ablation confirmed that each component contributed a distinct value. The calibrated outputs directly support risk-based reserve sizing, stochastic unit commitment, and demand response activation. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2603_07899 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | Bayesian Transformer for Probabilistic Load Forecasting in Smart Grids Debnath, Sajib Mia, Md. Uzzal Machine Learning The reliable operation of modern power grids requires probabilistic load forecasts with well-calibrated uncertainty estimates. However, existing deep learning models produce overconfident point predictions that fail catastrophically under extreme weather distributional shifts. This study proposes a Bayesian Transformer (BT) framework that integrates three complementary uncertainty mechanisms into a PatchTST backbone: Monte Carlo Dropout for epistemic parameter uncertainty, variational feed-forward layers with log-uniform weight priors, and stochastic attention with learnable Gaussian noise perturbations on pre-softmax logits, representing, to the best of our knowledge, the first application of Bayesian attention to probabilistic load forecasting. A seven-level multi-quantile pinball-loss prediction head and post-training isotonic regression calibration produce sharp, near-nominally covered prediction intervals. Evaluation of five grid datasets (PJM, ERCOT, ENTSO-E Germany, France, and Great Britain) augmented with NOAA covariates across 24, 48, and 168-hour horizons demonstrates state-of-the-art performance. On the primary benchmark (PJM, H=24h), BT achieves a CRPS of 0.0289, improving 7.4% over Deep Ensembles and 29.9% over the deterministic LSTM, with 90.4% PICP at the 90% nominal level and the narrowest prediction intervals (4,960 MW) among all probabilistic baselines. During heat-wave and cold snap events, BT maintained 89.6% and 90.1% PICP respectively, versus 64.7% and 67.2% for the deterministic LSTM, confirming that Bayesian epistemic uncertainty naturally widens intervals for out-of-distribution inputs. Calibration remained stable across all horizons (89.8-90.4% PICP), while ablation confirmed that each component contributed a distinct value. The calibrated outputs directly support risk-based reserve sizing, stochastic unit commitment, and demand response activation. |
| title | Bayesian Transformer for Probabilistic Load Forecasting in Smart Grids |
| topic | Machine Learning |
| url | https://arxiv.org/abs/2603.07899 |