Towards Trustworthy Selective Generation: Reliability-Guided Diffusion for Ultra-Low-Field to High-Field MRI Synthesis

Fuente: arXiv
Guardado en:
Detalles Bibliográficos
Autores principales: Zhang, Zhenxuan, Jing, Peiyuan, Yuan, Ruicheng, Hu, Liwei, Wang, Anbang, Wang, Fanwen, Wu, Yinzhe, Islam, Kh Tohidul, Chen, Zhaolin, Wang, Zi, Lally, Peter, Yang, Guang
Formato: Preprint
Publicado: 2026
Materias:
Acceso en línea:
Etiquetas: Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
_version_ 1866917333694414848
author Zhang, Zhenxuan
Jing, Peiyuan
Yuan, Ruicheng
Hu, Liwei
Wang, Anbang
Wang, Fanwen
Wu, Yinzhe
Islam, Kh Tohidul
Chen, Zhaolin
Wang, Zi
Lally, Peter
Yang, Guang
author_facet Zhang, Zhenxuan
Jing, Peiyuan
Yuan, Ruicheng
Hu, Liwei
Wang, Anbang
Wang, Fanwen
Wu, Yinzhe
Islam, Kh Tohidul
Chen, Zhaolin
Wang, Zi
Lally, Peter
Yang, Guang
contents Low-field to high-field MRI synthesis has emerged as a cost-effective strategy to enhance image quality under hardware and acquisition constraints, particularly in scenarios where access to high-field scanners is limited or impractical. Despite recent progress in diffusion models, diffusion-based approaches often struggle to balance fine-detail recovery and structural fidelity. In particular, the uncontrolled generation of high-resolution details in structurally ambiguous regions may introduce anatomically inconsistent patterns, such as spurious edges or artificial texture variations. These artifacts can bias downstream quantitative analysis. For example, they may cause inaccurate tissue boundary delineation or erroneous volumetric estimation, ultimately reducing clinical trust in synthesized images. These limitations highlight the need for generative models that are not only visually accurate but also spatially reliable and anatomically consistent. To address this issue, we propose a reliability-aware diffusion framework (ReDiff) that improves synthesis robustness at both the sampling and post-generation stages. Specifically, we introduce a reliability-guided sampling strategy to suppress unreliable responses during the denoising process. We further develop an uncertainty-aware multi-candidate selection scheme to enhance the reliability of the final prediction. Experiments on multi-center MRI datasets demonstrate improved structural fidelity and reduced artifacts compared with state-of-the-art methods.
format Preprint
id arxiv_https___arxiv_org_abs_2603_11325
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Towards Trustworthy Selective Generation: Reliability-Guided Diffusion for Ultra-Low-Field to High-Field MRI Synthesis
Zhang, Zhenxuan
Jing, Peiyuan
Yuan, Ruicheng
Hu, Liwei
Wang, Anbang
Wang, Fanwen
Wu, Yinzhe
Islam, Kh Tohidul
Chen, Zhaolin
Wang, Zi
Lally, Peter
Yang, Guang
Computer Vision and Pattern Recognition
Low-field to high-field MRI synthesis has emerged as a cost-effective strategy to enhance image quality under hardware and acquisition constraints, particularly in scenarios where access to high-field scanners is limited or impractical. Despite recent progress in diffusion models, diffusion-based approaches often struggle to balance fine-detail recovery and structural fidelity. In particular, the uncontrolled generation of high-resolution details in structurally ambiguous regions may introduce anatomically inconsistent patterns, such as spurious edges or artificial texture variations. These artifacts can bias downstream quantitative analysis. For example, they may cause inaccurate tissue boundary delineation or erroneous volumetric estimation, ultimately reducing clinical trust in synthesized images. These limitations highlight the need for generative models that are not only visually accurate but also spatially reliable and anatomically consistent. To address this issue, we propose a reliability-aware diffusion framework (ReDiff) that improves synthesis robustness at both the sampling and post-generation stages. Specifically, we introduce a reliability-guided sampling strategy to suppress unreliable responses during the denoising process. We further develop an uncertainty-aware multi-candidate selection scheme to enhance the reliability of the final prediction. Experiments on multi-center MRI datasets demonstrate improved structural fidelity and reduced artifacts compared with state-of-the-art methods.
title Towards Trustworthy Selective Generation: Reliability-Guided Diffusion for Ultra-Low-Field to High-Field MRI Synthesis
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2603.11325