Reinforcing the Weakest Links: Modernizing SIENA with Targeted Deep Learning Integration

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Raciti, Riccardo, Puglisi, Lemuel, Guarnera, Francesco, Ravì, Daniele, Battiato, Sebastiano
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866912964829773824
author Raciti, Riccardo
Puglisi, Lemuel
Guarnera, Francesco
Ravì, Daniele
Battiato, Sebastiano
author_facet Raciti, Riccardo
Puglisi, Lemuel
Guarnera, Francesco
Ravì, Daniele
Battiato, Sebastiano
contents Percentage Brain Volume Change (PBVC) derived from Magnetic Resonance Imaging (MRI) is a widely used biomarker of brain atrophy, with SIENA among the most established methods for its estimation. However, SIENA relies on classical image processing steps, particularly skull stripping and tissue segmentation, whose failures can propagate through the pipeline and bias atrophy estimates. In this work, we examine whether targeted deep learning substitutions can improve SIENA while preserving its established and interpretable framework. To this end, we integrate SynthStrip and SynthSeg into SIENA and evaluate three pipeline variants on the ADNI and PPMI longitudinal cohorts. Performance is assessed using three complementary criteria: correlation with longitudinal clinical and structural decline, scan-order consistency, and end-to-end runtime. Replacing the skull-stripping module yields the most consistent gains: in ADNI, it substantially strengthens associations between PBVC and multiple measures of disease progression relative to the standard SIENA pipeline, while across both datasets it markedly improves robustness under scan reversal. The fully integrated pipeline achieves the strongest scan-order consistency, reducing the error by up to 99.1%. In addition, GPU-enabled variants reduce execution time by up to 46% while maintaining CPU runtimes comparable to standard SIENA. Overall, these findings show that deep learning can meaningfully strengthen established longitudinal atrophy pipelines when used to reinforce their weakest image processing steps. More broadly, this study highlights the value of modularly modernizing clinically trusted neuroimaging tools without sacrificing their interpretability. Code is publicly available at https://github.com/Raciti/Enhanced-SIENA.git.
format Preprint
id arxiv_https___arxiv_org_abs_2603_12951
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Reinforcing the Weakest Links: Modernizing SIENA with Targeted Deep Learning Integration
Raciti, Riccardo
Puglisi, Lemuel
Guarnera, Francesco
Ravì, Daniele
Battiato, Sebastiano
Image and Video Processing
Computer Vision and Pattern Recognition
Percentage Brain Volume Change (PBVC) derived from Magnetic Resonance Imaging (MRI) is a widely used biomarker of brain atrophy, with SIENA among the most established methods for its estimation. However, SIENA relies on classical image processing steps, particularly skull stripping and tissue segmentation, whose failures can propagate through the pipeline and bias atrophy estimates. In this work, we examine whether targeted deep learning substitutions can improve SIENA while preserving its established and interpretable framework. To this end, we integrate SynthStrip and SynthSeg into SIENA and evaluate three pipeline variants on the ADNI and PPMI longitudinal cohorts. Performance is assessed using three complementary criteria: correlation with longitudinal clinical and structural decline, scan-order consistency, and end-to-end runtime. Replacing the skull-stripping module yields the most consistent gains: in ADNI, it substantially strengthens associations between PBVC and multiple measures of disease progression relative to the standard SIENA pipeline, while across both datasets it markedly improves robustness under scan reversal. The fully integrated pipeline achieves the strongest scan-order consistency, reducing the error by up to 99.1%. In addition, GPU-enabled variants reduce execution time by up to 46% while maintaining CPU runtimes comparable to standard SIENA. Overall, these findings show that deep learning can meaningfully strengthen established longitudinal atrophy pipelines when used to reinforce their weakest image processing steps. More broadly, this study highlights the value of modularly modernizing clinically trusted neuroimaging tools without sacrificing their interpretability. Code is publicly available at https://github.com/Raciti/Enhanced-SIENA.git.
title Reinforcing the Weakest Links: Modernizing SIENA with Targeted Deep Learning Integration
topic Image and Video Processing
Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2603.12951