Crossover Frequency as a Model-Independent Viscoelastic Constant for Soft Tissue Biomechanics

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Ruhland, Laura, Guo, Jing, Sack, Ingolf, Willner, Kai
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911514505510912
author Ruhland, Laura
Guo, Jing
Sack, Ingolf
Willner, Kai
author_facet Ruhland, Laura
Guo, Jing
Sack, Ingolf
Willner, Kai
contents Magnetic resonance elastography (MRE) and related elastography techniques are emerging as quantitative diagnostic tools for assessing tissue microstructure and pathology. To determine descriptive parameters of the tissues' properties, a frequency-dependent viscoelastic material model is required, which is calibrated to the measured response in a parameter identification process. However, the selection of this model and the fitting strategy is challenging, since it may influence the identified viscoelastic parameters notably. Here, we address this limitation by proposing the crossover frequency (fc, defined as the frequency at which storage and loss moduli intersect G'(fc) = G''(fc)) as a model-independent viscoelastic constant for soft tissues. Fresh porcine specimens of the corona radiata, the putamen, the thalamus, and the liver were investigated using tabletop MRE and the frequency-dependent viscoelasticity was characterized with a fractional Kelvin-Voigt model. By validating the crossover frequency against the viscoelastic parameters, we demonstrated that the crossover frequency accurately reflects the viscoelastic behavior, independent of the material model or the fitting strategy. Across all samples, fc distinguished brain regions and separated brain from liver tissue by median frequencies of 85Hz (95% CI: 69-269Hz) in the corona radiata, 423Hz (95% CI: 316-575Hz) in the putamen, 426Hz (95% CI: 302-601Hz) in the thalamus and 1174Hz (95% CI: 1074-1300Hz) in the liver (p<0.001). These results suggest that crossover frequencies capture distinct viscoelastic fingerprints without requiring viscoelastic model selection. The crossover frequency may therefore serve as a practical, model-independent biomaterial constant to improve comparability of viscoelastic measurements across elastography studies.
format Preprint
id arxiv_https___arxiv_org_abs_2603_13268
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Crossover Frequency as a Model-Independent Viscoelastic Constant for Soft Tissue Biomechanics
Ruhland, Laura
Guo, Jing
Sack, Ingolf
Willner, Kai
Medical Physics
Materials Science
Biological Physics
Magnetic resonance elastography (MRE) and related elastography techniques are emerging as quantitative diagnostic tools for assessing tissue microstructure and pathology. To determine descriptive parameters of the tissues' properties, a frequency-dependent viscoelastic material model is required, which is calibrated to the measured response in a parameter identification process. However, the selection of this model and the fitting strategy is challenging, since it may influence the identified viscoelastic parameters notably. Here, we address this limitation by proposing the crossover frequency (fc, defined as the frequency at which storage and loss moduli intersect G'(fc) = G''(fc)) as a model-independent viscoelastic constant for soft tissues. Fresh porcine specimens of the corona radiata, the putamen, the thalamus, and the liver were investigated using tabletop MRE and the frequency-dependent viscoelasticity was characterized with a fractional Kelvin-Voigt model. By validating the crossover frequency against the viscoelastic parameters, we demonstrated that the crossover frequency accurately reflects the viscoelastic behavior, independent of the material model or the fitting strategy. Across all samples, fc distinguished brain regions and separated brain from liver tissue by median frequencies of 85Hz (95% CI: 69-269Hz) in the corona radiata, 423Hz (95% CI: 316-575Hz) in the putamen, 426Hz (95% CI: 302-601Hz) in the thalamus and 1174Hz (95% CI: 1074-1300Hz) in the liver (p<0.001). These results suggest that crossover frequencies capture distinct viscoelastic fingerprints without requiring viscoelastic model selection. The crossover frequency may therefore serve as a practical, model-independent biomaterial constant to improve comparability of viscoelastic measurements across elastography studies.
title Crossover Frequency as a Model-Independent Viscoelastic Constant for Soft Tissue Biomechanics
topic Medical Physics
Materials Science
Biological Physics
url https://arxiv.org/abs/2603.13268