Development of a high-field pulsed magnet and optical fiber coupled cryostat system for magneto-photoluminescence measurements

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Kalauni, Deepesh, Mukhuti, Kingshuk, Peng, Tao, Bansal, Bhavtosh
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912965799706624
author Kalauni, Deepesh
Mukhuti, Kingshuk
Peng, Tao
Bansal, Bhavtosh
author_facet Kalauni, Deepesh
Mukhuti, Kingshuk
Peng, Tao
Bansal, Bhavtosh
contents This paper presents the development of a high field pulsed magnet system combined with an optical fiber-coupled low temperature cryostat for magneto-photoluminescence measurements. A novel aspect of our system is the use of electrolyte capacitors in a 75 kJ capacitor bank to drive the pulsed magnet, enabling the generation of high magnetic fields at a relatively low charging voltage (400 V). The zylon reinforced wire wound magnet coil achieves a maximum field strength of 35 tesla with a magnetic field rise time of 10 ms. The integrated cryostat was developed to meet the specific requirements of magneto-photoluminescence experiments using a 4 K helium closed-cycle cryocooler to provide a stable low-temperature environment down to 5 K.
format Preprint
id arxiv_https___arxiv_org_abs_2603_13436
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Development of a high-field pulsed magnet and optical fiber coupled cryostat system for magneto-photoluminescence measurements
Kalauni, Deepesh
Mukhuti, Kingshuk
Peng, Tao
Bansal, Bhavtosh
Instrumentation and Detectors
Materials Science
This paper presents the development of a high field pulsed magnet system combined with an optical fiber-coupled low temperature cryostat for magneto-photoluminescence measurements. A novel aspect of our system is the use of electrolyte capacitors in a 75 kJ capacitor bank to drive the pulsed magnet, enabling the generation of high magnetic fields at a relatively low charging voltage (400 V). The zylon reinforced wire wound magnet coil achieves a maximum field strength of 35 tesla with a magnetic field rise time of 10 ms. The integrated cryostat was developed to meet the specific requirements of magneto-photoluminescence experiments using a 4 K helium closed-cycle cryocooler to provide a stable low-temperature environment down to 5 K.
title Development of a high-field pulsed magnet and optical fiber coupled cryostat system for magneto-photoluminescence measurements
topic Instrumentation and Detectors
Materials Science
url https://arxiv.org/abs/2603.13436