4D reconstruction of alumina laser melt pools at 25 kHz via operando X-ray multi-projection imaging

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Witte, Lars, Jermann, Eliot, Hu, Zhe, Yao, Zisheng, Asimakopoulou, Eleni Myrto, Rogalinski, Julia Katharina, Zhang, Yuhe, Nygård, Kim, Makowska, Malgorzata G., Bambach, Markus, Afrasiabi, Mohamadreza, Villanueva-Perez, Pablo
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866911517934354432
author Witte, Lars
Jermann, Eliot
Hu, Zhe
Yao, Zisheng
Asimakopoulou, Eleni Myrto
Rogalinski, Julia Katharina
Zhang, Yuhe
Nygård, Kim
Makowska, Malgorzata G.
Bambach, Markus
Afrasiabi, Mohamadreza
Villanueva-Perez, Pablo
author_facet Witte, Lars
Jermann, Eliot
Hu, Zhe
Yao, Zisheng
Asimakopoulou, Eleni Myrto
Rogalinski, Julia Katharina
Zhang, Yuhe
Nygård, Kim
Makowska, Malgorzata G.
Bambach, Markus
Afrasiabi, Mohamadreza
Villanueva-Perez, Pablo
contents Advancing additive manufacturing, e.g., laser powder-bed fusion (LPBF), requires resolving rapid processes such as melt-pool dynamics and keyhole evolution in 4D (3D + time). Operando X-ray tomography is a state-of-the-art approach for 4D characterization, but its temporal resolution is fundamentally constrained by the sample rotation speed, limiting achievable 4D imaging rates and preventing the resolution of these fast phenomena. Here we present rotation-enabled X-ray Multi-Projection Imaging (rotation-XMPI), which captures three angularly resolved projections per time step and thereby decouples temporal resolution from the sample rotation speed. Combined with a self-supervised deep-learning reconstruction framework for multi-angle inputs, rotation-XMPI enables high-fidelity 4D imaging at unprecedented speed. We demonstrate the approach in an operando alumina laser-remelting experiment at MAX IV using three beamlets combined with 25 Hz sample rotation. Rotation-XMPI resolves melt-pool morphology and keyhole evolution; in contrast, conventional and limited-angle tomography remain rotation-limited, and motion blur prevents resolving these dynamics. Overall, rotation-XMPI delivers a 250-fold increase relative to state-of-the-art melt-pool imaging, effectively achieving 25,000 reconstructed volumes per second. This method establishes a practical route to scalable ultrafast 4D imaging for additive manufacturing and other materials processes.
format Preprint
id arxiv_https___arxiv_org_abs_2603_14391
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle 4D reconstruction of alumina laser melt pools at 25 kHz via operando X-ray multi-projection imaging
Witte, Lars
Jermann, Eliot
Hu, Zhe
Yao, Zisheng
Asimakopoulou, Eleni Myrto
Rogalinski, Julia Katharina
Zhang, Yuhe
Nygård, Kim
Makowska, Malgorzata G.
Bambach, Markus
Afrasiabi, Mohamadreza
Villanueva-Perez, Pablo
Optics
Image and Video Processing
Advancing additive manufacturing, e.g., laser powder-bed fusion (LPBF), requires resolving rapid processes such as melt-pool dynamics and keyhole evolution in 4D (3D + time). Operando X-ray tomography is a state-of-the-art approach for 4D characterization, but its temporal resolution is fundamentally constrained by the sample rotation speed, limiting achievable 4D imaging rates and preventing the resolution of these fast phenomena. Here we present rotation-enabled X-ray Multi-Projection Imaging (rotation-XMPI), which captures three angularly resolved projections per time step and thereby decouples temporal resolution from the sample rotation speed. Combined with a self-supervised deep-learning reconstruction framework for multi-angle inputs, rotation-XMPI enables high-fidelity 4D imaging at unprecedented speed. We demonstrate the approach in an operando alumina laser-remelting experiment at MAX IV using three beamlets combined with 25 Hz sample rotation. Rotation-XMPI resolves melt-pool morphology and keyhole evolution; in contrast, conventional and limited-angle tomography remain rotation-limited, and motion blur prevents resolving these dynamics. Overall, rotation-XMPI delivers a 250-fold increase relative to state-of-the-art melt-pool imaging, effectively achieving 25,000 reconstructed volumes per second. This method establishes a practical route to scalable ultrafast 4D imaging for additive manufacturing and other materials processes.
title 4D reconstruction of alumina laser melt pools at 25 kHz via operando X-ray multi-projection imaging
topic Optics
Image and Video Processing
url https://arxiv.org/abs/2603.14391