Rethinking Frequency Control in Power Systems

Fuente: arXiv
Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Kerci, Taulant, Vaca, Angel, Groom, Andrew, Matevosyan, Julia, Milano, Federico
Format: Preprint
Veröffentlicht: 2026
Schlagworte:
Online-Zugang:
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
_version_ 1866911520921747456
author Kerci, Taulant
Vaca, Angel
Groom, Andrew
Matevosyan, Julia
Milano, Federico
author_facet Kerci, Taulant
Vaca, Angel
Groom, Andrew
Matevosyan, Julia
Milano, Federico
contents Frequency control in power systems is implemented in a hierarchical structure traditionally known as primary frequency control (PFC), secondary frequency control (SFC) and tertiary control reserve (TCR) and, some jurisdictions, include time error control (TEC) as well. This hierarchical structure has been designed around a century ago based on timescales separation, that is, approximately an order of magnitude difference between each control structure. This paper argues, based on real-world observations as well as detailed dynamic simulations on a model of the All-Island power system (AIPS) of Ireland, that this frequency control structure is not necessary in current and future converter-dominated power grids. The paper proposes to redesign this structure by removing the SFC and TCR and rely on PFC and a real-time energy market. The PFC is responsible for addressing fast power imbalances in timescales of tens of ms to few minutes (e.g., 100 ms to 5 minutes) while the real-time energy market is responsible for addressing longer imbalances in timescales of minutes to hours (e.g., 5 minutes to 1 hour). TEC, on the other hand, is considered as optional.
format Preprint
id arxiv_https___arxiv_org_abs_2603_15889
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Rethinking Frequency Control in Power Systems
Kerci, Taulant
Vaca, Angel
Groom, Andrew
Matevosyan, Julia
Milano, Federico
Systems and Control
Frequency control in power systems is implemented in a hierarchical structure traditionally known as primary frequency control (PFC), secondary frequency control (SFC) and tertiary control reserve (TCR) and, some jurisdictions, include time error control (TEC) as well. This hierarchical structure has been designed around a century ago based on timescales separation, that is, approximately an order of magnitude difference between each control structure. This paper argues, based on real-world observations as well as detailed dynamic simulations on a model of the All-Island power system (AIPS) of Ireland, that this frequency control structure is not necessary in current and future converter-dominated power grids. The paper proposes to redesign this structure by removing the SFC and TCR and rely on PFC and a real-time energy market. The PFC is responsible for addressing fast power imbalances in timescales of tens of ms to few minutes (e.g., 100 ms to 5 minutes) while the real-time energy market is responsible for addressing longer imbalances in timescales of minutes to hours (e.g., 5 minutes to 1 hour). TEC, on the other hand, is considered as optional.
title Rethinking Frequency Control in Power Systems
topic Systems and Control
url https://arxiv.org/abs/2603.15889