Spatial resolution improvement of PICOSEC Micromegas precise timing detectors
Fuente:
arXiv
Guardado en:
| Autores principales: | , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , , |
|---|---|
| Formato: | Preprint |
| Publicado: |
2026
|
| Materias: | |
| Acceso en línea: | |
| Etiquetas: |
Agregar Etiqueta
Sin Etiquetas, Sea el primero en etiquetar este registro!
|
| _version_ | 1866911529450864640 |
|---|---|
| author | Brunbauer, F. M. Aleksan, R. Angelis, Y. Aune, S. Bortfeldt, J. Brunoldi, M. Datta, J. Desforge, D. Fanourakis, G. Fiorina, D. Floethner, K. J. Gallinaro, M. Garcia, F. Giomataris, I. Gnanvo, K. Huang, Q. Iguaz, F. J. Janssens, D. Kallitsopoulou, A. Karakoulias, I. Kovacic, M. Legou, P. Lisowska, M. Liu, J. Lupberger, M. Maniatis, I. Micetic, M. Muller, H. Oliveri, E. Papaevangelou, T. Pomorski, M. Ropelewski, L. Salamon, K. Sampsonidis, D. Scharenberg, L. Schneider, T. Scorsone, E. Sohl, L. Shankman, N. van Stenis, M. Tsipolitis, Y. Tzamarias, S. E. Utrobicic, A. Vai, I. Veenhof, R. Vitulo, P. Wang, X. White, S. Zhang, Z. Zhou, Y. |
| author_facet | Brunbauer, F. M. Aleksan, R. Angelis, Y. Aune, S. Bortfeldt, J. Brunoldi, M. Datta, J. Desforge, D. Fanourakis, G. Fiorina, D. Floethner, K. J. Gallinaro, M. Garcia, F. Giomataris, I. Gnanvo, K. Huang, Q. Iguaz, F. J. Janssens, D. Kallitsopoulou, A. Karakoulias, I. Kovacic, M. Legou, P. Lisowska, M. Liu, J. Lupberger, M. Maniatis, I. Micetic, M. Muller, H. Oliveri, E. Papaevangelou, T. Pomorski, M. Ropelewski, L. Salamon, K. Sampsonidis, D. Scharenberg, L. Schneider, T. Scorsone, E. Sohl, L. Shankman, N. van Stenis, M. Tsipolitis, Y. Tzamarias, S. E. Utrobicic, A. Vai, I. Veenhof, R. Vitulo, P. Wang, X. White, S. Zhang, Z. Zhou, Y. |
| contents | The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2603_18733 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | Spatial resolution improvement of PICOSEC Micromegas precise timing detectors Brunbauer, F. M. Aleksan, R. Angelis, Y. Aune, S. Bortfeldt, J. Brunoldi, M. Datta, J. Desforge, D. Fanourakis, G. Fiorina, D. Floethner, K. J. Gallinaro, M. Garcia, F. Giomataris, I. Gnanvo, K. Huang, Q. Iguaz, F. J. Janssens, D. Kallitsopoulou, A. Karakoulias, I. Kovacic, M. Legou, P. Lisowska, M. Liu, J. Lupberger, M. Maniatis, I. Micetic, M. Muller, H. Oliveri, E. Papaevangelou, T. Pomorski, M. Ropelewski, L. Salamon, K. Sampsonidis, D. Scharenberg, L. Schneider, T. Scorsone, E. Sohl, L. Shankman, N. van Stenis, M. Tsipolitis, Y. Tzamarias, S. E. Utrobicic, A. Vai, I. Veenhof, R. Vitulo, P. Wang, X. White, S. Zhang, Z. Zhou, Y. Instrumentation and Detectors The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously. |
| title | Spatial resolution improvement of PICOSEC Micromegas precise timing detectors |
| topic | Instrumentation and Detectors |
| url | https://arxiv.org/abs/2603.18733 |