Saved in:
Bibliographic Details
Main Author: Zheng, Yifeng
Format: Preprint
Published: 2026
Subjects:
Online Access:https://arxiv.org/abs/2603.20806
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908994818277376
author Zheng, Yifeng
author_facet Zheng, Yifeng
contents Multi-label fundus diagnosis requires features that capture both fine-grained lesions and large-scale retinal structure. Many multi-scale medical vision models address this challenge through explicit frequency decomposition, but our ablation studies show that such heuristics provide limited benefit in this setting: replacing the proposed simple dual-resolution stem with Octave Convolution increased parameters by 35% and computation by a 2.23-fold increase in computation; without improving mean accuracy, while a fixed wavelet-based variant performed substantially worse. Motivated by these findings, we propose Clifford-M, a lightweight backbone that replaces both feed-forward expansion and frequency-splitting modules with sparse geometric interaction. The model is built on a Clifford-style rolling product that jointly captures alignment and structural variation with linear complexity, enabling efficient cross-scale fusion and self-refinement in a compact dual-resolution architecture. Without pre-training, Clifford-M achieves a mean AUC-ROC of 0.8142 and a mean macro-F1 (optimal threshold) of 0.5481 on ODIR-5K using only 0.85M parameters, outperforming substantially larger mid-scale CNN baselines under the same training protocol. When evaluated on RFMiD without fine-tuning, it attains 0.7425 +/- 0.0198 macro AUC and 0.7610 +/- 0.0344 micro AUC, indicating reasonable robustness to cross-dataset shift. These results suggest that competitive and efficient fundus diagnosis can be achieved without explicit frequency engineering, provided that the core feature interaction is designed to capture multi-scale structure directly.
format Preprint
id arxiv_https___arxiv_org_abs_2603_20806
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Less is More in Semantic Space: Intrinsic Decoupling via Clifford-M for Fundus Image Classification
Zheng, Yifeng
Computer Vision and Pattern Recognition
Multi-label fundus diagnosis requires features that capture both fine-grained lesions and large-scale retinal structure. Many multi-scale medical vision models address this challenge through explicit frequency decomposition, but our ablation studies show that such heuristics provide limited benefit in this setting: replacing the proposed simple dual-resolution stem with Octave Convolution increased parameters by 35% and computation by a 2.23-fold increase in computation; without improving mean accuracy, while a fixed wavelet-based variant performed substantially worse. Motivated by these findings, we propose Clifford-M, a lightweight backbone that replaces both feed-forward expansion and frequency-splitting modules with sparse geometric interaction. The model is built on a Clifford-style rolling product that jointly captures alignment and structural variation with linear complexity, enabling efficient cross-scale fusion and self-refinement in a compact dual-resolution architecture. Without pre-training, Clifford-M achieves a mean AUC-ROC of 0.8142 and a mean macro-F1 (optimal threshold) of 0.5481 on ODIR-5K using only 0.85M parameters, outperforming substantially larger mid-scale CNN baselines under the same training protocol. When evaluated on RFMiD without fine-tuning, it attains 0.7425 +/- 0.0198 macro AUC and 0.7610 +/- 0.0344 micro AUC, indicating reasonable robustness to cross-dataset shift. These results suggest that competitive and efficient fundus diagnosis can be achieved without explicit frequency engineering, provided that the core feature interaction is designed to capture multi-scale structure directly.
title Less is More in Semantic Space: Intrinsic Decoupling via Clifford-M for Fundus Image Classification
topic Computer Vision and Pattern Recognition
url https://arxiv.org/abs/2603.20806