Polymer identification via undetected photons using a low footprint nonlinear interferometer
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , , , , , , , |
|---|---|
| Format: | Preprint |
| Publié: |
2026
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866911538407800832 |
|---|---|
| author | Sherwani, Atta Ur Rehman Pearce, Emma Hildenstein, Philipp Mauerhoff, Felix Sahm, Alexander Paschke, Katrin Chrzanowski, Helen M. Ramelow, Sven |
| author_facet | Sherwani, Atta Ur Rehman Pearce, Emma Hildenstein, Philipp Mauerhoff, Felix Sahm, Alexander Paschke, Katrin Chrzanowski, Helen M. Ramelow, Sven |
| contents | Plastic pollution has become a critical global challenge, with microplastics pervading ecosystems and entering human food chains. Effectively monitoring this widespread contamination demands rapid, reliable, and portable material identification techniques that often elude conventional Raman and FTIR spectroscopy. Undetected photon spectroscopy within a nonlinear interferometer (NLI) offers a solution, allowing the retrieval of mid-infrared absorption spectra by detecting only near-infrared signal photons using standard silicon-based technology. Here, we demonstrate a highly compact, micro-integrated, thermally-stabilised NLI with a Michelson-like geometry designed for the rapid spectroscopy of plastics. We benchmarked its room-temperature performance, demonstrating a signal-to-noise ratio of 34 with a measurement rate of 100 Hz and a spectral resolution of 6 cm$^{-1}$. We show that we can accurately and rapidly retrieve the characteristic vibrational absorption spectra of common polymers such as polypropylene, polyethene, and polystyrene, without using mid-infrared technology. These results establish our compact module as a promising field-deployable platform for robust, real-time environmental monitoring systems and other mid-infrared spectroscopy applications. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2603_22253 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | Polymer identification via undetected photons using a low footprint nonlinear interferometer Sherwani, Atta Ur Rehman Pearce, Emma Hildenstein, Philipp Mauerhoff, Felix Sahm, Alexander Paschke, Katrin Chrzanowski, Helen M. Ramelow, Sven Quantum Physics Applied Physics Instrumentation and Detectors Optics Plastic pollution has become a critical global challenge, with microplastics pervading ecosystems and entering human food chains. Effectively monitoring this widespread contamination demands rapid, reliable, and portable material identification techniques that often elude conventional Raman and FTIR spectroscopy. Undetected photon spectroscopy within a nonlinear interferometer (NLI) offers a solution, allowing the retrieval of mid-infrared absorption spectra by detecting only near-infrared signal photons using standard silicon-based technology. Here, we demonstrate a highly compact, micro-integrated, thermally-stabilised NLI with a Michelson-like geometry designed for the rapid spectroscopy of plastics. We benchmarked its room-temperature performance, demonstrating a signal-to-noise ratio of 34 with a measurement rate of 100 Hz and a spectral resolution of 6 cm$^{-1}$. We show that we can accurately and rapidly retrieve the characteristic vibrational absorption spectra of common polymers such as polypropylene, polyethene, and polystyrene, without using mid-infrared technology. These results establish our compact module as a promising field-deployable platform for robust, real-time environmental monitoring systems and other mid-infrared spectroscopy applications. |
| title | Polymer identification via undetected photons using a low footprint nonlinear interferometer |
| topic | Quantum Physics Applied Physics Instrumentation and Detectors Optics |
| url | https://arxiv.org/abs/2603.22253 |