Experimental Characterisation of Distributed Reactive Power Sharing under Communication-Induced Stress in Parallel Grid-Forming Inverters

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Anccas, E. D. Gomez, MacPherson, E. A., Tegeler, J., Röbert, K., Fischer, M., Hans, C. A., Schulz, D.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908909388693504
author Anccas, E. D. Gomez
MacPherson, E. A.
Tegeler, J.
Röbert, K.
Fischer, M.
Hans, C. A.
Schulz, D.
author_facet Anccas, E. D. Gomez
MacPherson, E. A.
Tegeler, J.
Röbert, K.
Fischer, M.
Hans, C. A.
Schulz, D.
contents Synchronisation of parallel grid-forming inverters is crucial for stable operation of future power systems. This includes accurate and robust reactive power sharing under realistic operating conditions such as impedance mismatch and communication constraints. In this work, reactive power sharing by virtue of a distributed control law is investigated under line impedance mismatch. Furthermore, robustness and transient behaviour of the proposed approach are experimentally evaluated under communication-induced stressors including a fixed 3% packet loss and communication delays ranging from 50 ms to 100 ms, artificially introduced through a software-defined overlay. The study is conducted in a low-voltage laboratory-scale microgrid comprising two parallel grid-forming inverters, an AC load, and a grid-following battery system acting as a reactive power injector. The results show reactive power sharing convergence up to 90 ms communication delay, with a stability boundary between 90 ms and 100 ms, which decreases with increasing integral gain.
format Preprint
id arxiv_https___arxiv_org_abs_2603_22929
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Experimental Characterisation of Distributed Reactive Power Sharing under Communication-Induced Stress in Parallel Grid-Forming Inverters
Anccas, E. D. Gomez
MacPherson, E. A.
Tegeler, J.
Röbert, K.
Fischer, M.
Hans, C. A.
Schulz, D.
Systems and Control
Synchronisation of parallel grid-forming inverters is crucial for stable operation of future power systems. This includes accurate and robust reactive power sharing under realistic operating conditions such as impedance mismatch and communication constraints. In this work, reactive power sharing by virtue of a distributed control law is investigated under line impedance mismatch. Furthermore, robustness and transient behaviour of the proposed approach are experimentally evaluated under communication-induced stressors including a fixed 3% packet loss and communication delays ranging from 50 ms to 100 ms, artificially introduced through a software-defined overlay. The study is conducted in a low-voltage laboratory-scale microgrid comprising two parallel grid-forming inverters, an AC load, and a grid-following battery system acting as a reactive power injector. The results show reactive power sharing convergence up to 90 ms communication delay, with a stability boundary between 90 ms and 100 ms, which decreases with increasing integral gain.
title Experimental Characterisation of Distributed Reactive Power Sharing under Communication-Induced Stress in Parallel Grid-Forming Inverters
topic Systems and Control
url https://arxiv.org/abs/2603.22929