Rigid Motion Estimation using Accelerated Iterative Coordinate Descent (REACT) for MR Imaging

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Jang, Kwang Eun, Nishimura, Dwight G.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908909677051904
author Jang, Kwang Eun
Nishimura, Dwight G.
author_facet Jang, Kwang Eun
Nishimura, Dwight G.
contents Purpose: To develop a computationally viable autofocus method for estimating 3D rigid motion in MR imaging. Theory and Methods: The proposed method, REACT, assumes a piecewise-constant motion trajectory and estimates the rigid motion parameters of individual temporal segments by optimizing an image-quality metric. Coordinate descent is adopted to decompose the high-dimensional optimization problem into a series of subproblems, each updating the motion parameters of a single temporal segment. The cost function of each subproblem is assumed to be approximately locally convex under suitable acquisition conditions. Each subproblem is then solved using a derivative-free solver, thereby avoiding an exhaustive grid search. Numerical simulations were conducted to investigate the local convexity assumption. REACT was evaluated for respiratory motion correction on in vivo free-breathing coronary MR angiography datasets acquired using a 3D cones trajectory with image-based navigators (iNAVs). An autofocus nonrigid motion correction method was also evaluated for comparison. Coronary artery sharpness was quantified using unbounded image edge profile acutance (u-IEPA). Results: In numerical simulations, the objective surfaces of the subproblems were approximately locally convex when the current motion estimate was close to the desired solution. In the in vivo study, REACT yielded higher u-IEPA than the conventional iNAV-based translational motion-estimation method for both the left anterior descending artery (LAD) and right coronary artery. REACT also yielded higher u-IEPA for the LAD than the autofocus nonrigid motion correction method. Conclusion: This study demonstrates the feasibility of coordinate descent for autofocus motion correction in MR imaging.
format Preprint
id arxiv_https___arxiv_org_abs_2603_23096
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Rigid Motion Estimation using Accelerated Iterative Coordinate Descent (REACT) for MR Imaging
Jang, Kwang Eun
Nishimura, Dwight G.
Image and Video Processing
Purpose: To develop a computationally viable autofocus method for estimating 3D rigid motion in MR imaging. Theory and Methods: The proposed method, REACT, assumes a piecewise-constant motion trajectory and estimates the rigid motion parameters of individual temporal segments by optimizing an image-quality metric. Coordinate descent is adopted to decompose the high-dimensional optimization problem into a series of subproblems, each updating the motion parameters of a single temporal segment. The cost function of each subproblem is assumed to be approximately locally convex under suitable acquisition conditions. Each subproblem is then solved using a derivative-free solver, thereby avoiding an exhaustive grid search. Numerical simulations were conducted to investigate the local convexity assumption. REACT was evaluated for respiratory motion correction on in vivo free-breathing coronary MR angiography datasets acquired using a 3D cones trajectory with image-based navigators (iNAVs). An autofocus nonrigid motion correction method was also evaluated for comparison. Coronary artery sharpness was quantified using unbounded image edge profile acutance (u-IEPA). Results: In numerical simulations, the objective surfaces of the subproblems were approximately locally convex when the current motion estimate was close to the desired solution. In the in vivo study, REACT yielded higher u-IEPA than the conventional iNAV-based translational motion-estimation method for both the left anterior descending artery (LAD) and right coronary artery. REACT also yielded higher u-IEPA for the LAD than the autofocus nonrigid motion correction method. Conclusion: This study demonstrates the feasibility of coordinate descent for autofocus motion correction in MR imaging.
title Rigid Motion Estimation using Accelerated Iterative Coordinate Descent (REACT) for MR Imaging
topic Image and Video Processing
url https://arxiv.org/abs/2603.23096