Indirect monitoring of fast-charge cycling behavior of an energy-storage device-analysis of ambient temperature variations

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autore principale: Tikkanen, Pertti O.
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866918410577772544
author Tikkanen, Pertti O.
author_facet Tikkanen, Pertti O.
contents I present a reanalysis of temperature data from a publicly available certified laboratory report that documented the self-discharging behavior of an energy-storage device during 10 days. Graphs of temperature variations of both the tested device itself and the test chamber (fume hood) were given mainly for monitoring without further analysis, and variations in the ambient temperature signal were attributed to "other cells being cycled simultaneously in the same fume hood". I show that the ambient temperature signal alone -- together with some quite mild and reasonable assumptions -- allow to extract previously unpublished information on the simultaneously run test on the other cells: 1) the number of charge/discharge cycles 2) the cycle period, 3) the charge/discharge half-cycle asymmetry, and -- most significantly -- evidence that 4) the mentioned "other device" completed 338 full charge/discharge cycles at 3C rate at room temperature without any detectable thermal degradation signature.
format Preprint
id arxiv_https___arxiv_org_abs_2603_23541
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Indirect monitoring of fast-charge cycling behavior of an energy-storage device-analysis of ambient temperature variations
Tikkanen, Pertti O.
Instrumentation and Detectors
Materials Science
Applied Physics
Popular Physics
I present a reanalysis of temperature data from a publicly available certified laboratory report that documented the self-discharging behavior of an energy-storage device during 10 days. Graphs of temperature variations of both the tested device itself and the test chamber (fume hood) were given mainly for monitoring without further analysis, and variations in the ambient temperature signal were attributed to "other cells being cycled simultaneously in the same fume hood". I show that the ambient temperature signal alone -- together with some quite mild and reasonable assumptions -- allow to extract previously unpublished information on the simultaneously run test on the other cells: 1) the number of charge/discharge cycles 2) the cycle period, 3) the charge/discharge half-cycle asymmetry, and -- most significantly -- evidence that 4) the mentioned "other device" completed 338 full charge/discharge cycles at 3C rate at room temperature without any detectable thermal degradation signature.
title Indirect monitoring of fast-charge cycling behavior of an energy-storage device-analysis of ambient temperature variations
topic Instrumentation and Detectors
Materials Science
Applied Physics
Popular Physics
url https://arxiv.org/abs/2603.23541