Dominant Transient Stability of the Co-located PLL-Based Grid-Following Renewable Plant and Synchronous Condenser Systems

Fuente: arXiv
Salvato in:
Dettagli Bibliografici
Autori principali: Li, Bingfang, Yang, Songhao, Wang, Qinglan, Zhang, Xu, Xie, Huan, Qin, Chuan, Hao, Zhiguo
Natura: Preprint
Pubblicazione: 2026
Soggetti:
Accesso online:
Tags: Aggiungi Tag
Nessun Tag, puoi essere il primo ad aggiungerne!!
_version_ 1866910075234287616
author Li, Bingfang
Yang, Songhao
Wang, Qinglan
Zhang, Xu
Xie, Huan
Qin, Chuan
Hao, Zhiguo
author_facet Li, Bingfang
Yang, Songhao
Wang, Qinglan
Zhang, Xu
Xie, Huan
Qin, Chuan
Hao, Zhiguo
contents Deploying synchronous condensers (SynCons) near grid-following renewable energy sources (GFLRs) is an effective and increasingly adopted strategy for grid support. However, the potential transient instability risks in such configurations remain an open research question. This study investigates the mechanism of dominant synchronization instability source transition upon SynCon integration and proposes a straightforward approach to enhance system stability by leveraging their interactive characteristics. Firstly, a dual-timescale decoupling model is established, partitioning the system into a fast subsystem representing phase-locked loop (PLL) dynamics and a slow subsystem characterizing SynCon rotor dynamics. The study then examines the influence of SynCons on the transient stability of nearby PLLs and their own inherent stability. The study shows that SynCon's voltage-source characteristics and its time-scale separation from PLL dynamics can significantly enhance the PLL's stability boundary and mitigate non-coherent coupling effects among multiple GFLRs. However, the dominant instability source shifts from the fast-time-scale PLL to the slow-time-scale SynCon after SynCon integration. Crucially, this paper demonstrates that the damping effect of PLL control can also be transferred from the fast to the slow time scale, allowing well-tuned PLL damping to suppress SynCon rotor acceleration. Consequently, by utilizing SynCon's inherent support capability and a simple PLL damping loop, the transient stability of the co-located system can be significantly enhanced. These conclusions are validated using a converter controller-based Hardware-in-the-Loop (CHIL) platform.
format Preprint
id arxiv_https___arxiv_org_abs_2603_25192
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Dominant Transient Stability of the Co-located PLL-Based Grid-Following Renewable Plant and Synchronous Condenser Systems
Li, Bingfang
Yang, Songhao
Wang, Qinglan
Zhang, Xu
Xie, Huan
Qin, Chuan
Hao, Zhiguo
Systems and Control
Deploying synchronous condensers (SynCons) near grid-following renewable energy sources (GFLRs) is an effective and increasingly adopted strategy for grid support. However, the potential transient instability risks in such configurations remain an open research question. This study investigates the mechanism of dominant synchronization instability source transition upon SynCon integration and proposes a straightforward approach to enhance system stability by leveraging their interactive characteristics. Firstly, a dual-timescale decoupling model is established, partitioning the system into a fast subsystem representing phase-locked loop (PLL) dynamics and a slow subsystem characterizing SynCon rotor dynamics. The study then examines the influence of SynCons on the transient stability of nearby PLLs and their own inherent stability. The study shows that SynCon's voltage-source characteristics and its time-scale separation from PLL dynamics can significantly enhance the PLL's stability boundary and mitigate non-coherent coupling effects among multiple GFLRs. However, the dominant instability source shifts from the fast-time-scale PLL to the slow-time-scale SynCon after SynCon integration. Crucially, this paper demonstrates that the damping effect of PLL control can also be transferred from the fast to the slow time scale, allowing well-tuned PLL damping to suppress SynCon rotor acceleration. Consequently, by utilizing SynCon's inherent support capability and a simple PLL damping loop, the transient stability of the co-located system can be significantly enhanced. These conclusions are validated using a converter controller-based Hardware-in-the-Loop (CHIL) platform.
title Dominant Transient Stability of the Co-located PLL-Based Grid-Following Renewable Plant and Synchronous Condenser Systems
topic Systems and Control
url https://arxiv.org/abs/2603.25192