Portable laser-cooled ytterbium beam clock based on an ultra-narrow optical transition

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Offer, R. F., Klantsataya, E., Hilton, A. P., Strathearn, A., Hébert, N. Bourbeau, Billington, C. J., Watzdorf, S., Scholten, S. K., White, B., Nelligan, M., Stace, T. M., Luiten, A. N.
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866910075356971008
author Offer, R. F.
Klantsataya, E.
Hilton, A. P.
Strathearn, A.
Hébert, N. Bourbeau
Billington, C. J.
Watzdorf, S.
Scholten, S. K.
White, B.
Nelligan, M.
Stace, T. M.
Luiten, A. N.
author_facet Offer, R. F.
Klantsataya, E.
Hilton, A. P.
Strathearn, A.
Hébert, N. Bourbeau
Billington, C. J.
Watzdorf, S.
Scholten, S. K.
White, B.
Nelligan, M.
Stace, T. M.
Luiten, A. N.
contents The highest performance atomic clocks are based on interrogation of ultra-narrow optical transitions. There is now significant interest in developing these systems as a source of GNSS-independent time in deployed, dynamic environments. We report on the development and field trial of a portable optical atomic clock interrogating the 10mHz wide $^1$S$_0\rightarrow ^3$P$_0$ transition in ytterbium-171. To enable measurement of this ultra-narrow transition in a deployed setting we combine an atom-vapor based pre-stabilization reference with all-digital control and continuous clock spectroscopy of a transversely-cooled thermal atomic beam. Characterization of the short-term frequency stability within the lab demonstrates a modified Allan deviation of $2\times 10^{-14}/\sqrtτ$ for integration times up to 100s, reaching a best performance of $1.9\times 10^{-15}$ at 200s. The clock demonstrated the same performance after transport and install aboard a ship for field trial, and operated uninterrupted for multiple days whilst at sea. These results show a pathway towards truly portable optical frequency references based on the interrogation of ultra-narrow transitions.
format Preprint
id arxiv_https___arxiv_org_abs_2603_25261
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Portable laser-cooled ytterbium beam clock based on an ultra-narrow optical transition
Offer, R. F.
Klantsataya, E.
Hilton, A. P.
Strathearn, A.
Hébert, N. Bourbeau
Billington, C. J.
Watzdorf, S.
Scholten, S. K.
White, B.
Nelligan, M.
Stace, T. M.
Luiten, A. N.
Atomic Physics
The highest performance atomic clocks are based on interrogation of ultra-narrow optical transitions. There is now significant interest in developing these systems as a source of GNSS-independent time in deployed, dynamic environments. We report on the development and field trial of a portable optical atomic clock interrogating the 10mHz wide $^1$S$_0\rightarrow ^3$P$_0$ transition in ytterbium-171. To enable measurement of this ultra-narrow transition in a deployed setting we combine an atom-vapor based pre-stabilization reference with all-digital control and continuous clock spectroscopy of a transversely-cooled thermal atomic beam. Characterization of the short-term frequency stability within the lab demonstrates a modified Allan deviation of $2\times 10^{-14}/\sqrtτ$ for integration times up to 100s, reaching a best performance of $1.9\times 10^{-15}$ at 200s. The clock demonstrated the same performance after transport and install aboard a ship for field trial, and operated uninterrupted for multiple days whilst at sea. These results show a pathway towards truly portable optical frequency references based on the interrogation of ultra-narrow transitions.
title Portable laser-cooled ytterbium beam clock based on an ultra-narrow optical transition
topic Atomic Physics
url https://arxiv.org/abs/2603.25261