Trans-stenotic pressure gradient estimation using a modified Bernoulli equation

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Amiri, Ali, Padding, Johan T., Pirola, Selene, Hogendoorn, Willian
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866915892706672640
author Amiri, Ali
Padding, Johan T.
Pirola, Selene
Hogendoorn, Willian
author_facet Amiri, Ali
Padding, Johan T.
Pirola, Selene
Hogendoorn, Willian
contents Accurate non-invasive estimation of trans-stenotic pressure gradients remains a challenge. In clinical practice, pressure gradients are often estimated from velocity measurements using Bernoulli-based formulas, but these simplified relations do not explicitly account for how pressure losses change with the flow regime. Here, we introduce a modified Bernoulli (MB) formulation that incorporates regime-dependent pressure losses through a Reynolds-number-dependent loss coefficient. Steady in-vitro experiments were performed in an idealized stenosis model over physiologically relevant flow rates (0.65-3.9 L/min), combining direct pressure measurements with ultrasound imaging velocimetry and phase-contrast magnetic resonance imaging (PC-MRI) to measure velocities. The MB model was calibrated from the measured pressure drops and then evaluated against the simplified Bernoulli (SB) and extended Bernoulli (EB) formulations. Over the tested flow regime, MB agreed best with the measurements. SB and EB showed larger biases, with errors of roughly 10-55% (SB) and -15 to 25% (EB), and overestimated the pressure drop in the clinically relevant range. We additionally quantified the effect of PC-MRI in-plane pixel size on MRI-based pressure estimates. Coarse sampling of the stenosis throat led to systematic underestimation of flow rate and bulk velocity and, consequently, of the MB-predicted pressure drop. In contrast, the peak throat velocity was substantially less sensitive to pixel size, resulting in smaller estimation errors when used as input for the MB. Overall, the results demonstrate that accounting for flow-regime-dependent loss mechanisms enhances pressure drop estimation, and that sufficient sampling of the stenotic throat is crucial for MRI-based flow rate and pressure drop estimation. In addition, peak-velocity-based MB pressure drop estimations are less sensitive to pixel size.
format Preprint
id arxiv_https___arxiv_org_abs_2603_25523
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Trans-stenotic pressure gradient estimation using a modified Bernoulli equation
Amiri, Ali
Padding, Johan T.
Pirola, Selene
Hogendoorn, Willian
Fluid Dynamics
Medical Physics
Accurate non-invasive estimation of trans-stenotic pressure gradients remains a challenge. In clinical practice, pressure gradients are often estimated from velocity measurements using Bernoulli-based formulas, but these simplified relations do not explicitly account for how pressure losses change with the flow regime. Here, we introduce a modified Bernoulli (MB) formulation that incorporates regime-dependent pressure losses through a Reynolds-number-dependent loss coefficient. Steady in-vitro experiments were performed in an idealized stenosis model over physiologically relevant flow rates (0.65-3.9 L/min), combining direct pressure measurements with ultrasound imaging velocimetry and phase-contrast magnetic resonance imaging (PC-MRI) to measure velocities. The MB model was calibrated from the measured pressure drops and then evaluated against the simplified Bernoulli (SB) and extended Bernoulli (EB) formulations. Over the tested flow regime, MB agreed best with the measurements. SB and EB showed larger biases, with errors of roughly 10-55% (SB) and -15 to 25% (EB), and overestimated the pressure drop in the clinically relevant range. We additionally quantified the effect of PC-MRI in-plane pixel size on MRI-based pressure estimates. Coarse sampling of the stenosis throat led to systematic underestimation of flow rate and bulk velocity and, consequently, of the MB-predicted pressure drop. In contrast, the peak throat velocity was substantially less sensitive to pixel size, resulting in smaller estimation errors when used as input for the MB. Overall, the results demonstrate that accounting for flow-regime-dependent loss mechanisms enhances pressure drop estimation, and that sufficient sampling of the stenotic throat is crucial for MRI-based flow rate and pressure drop estimation. In addition, peak-velocity-based MB pressure drop estimations are less sensitive to pixel size.
title Trans-stenotic pressure gradient estimation using a modified Bernoulli equation
topic Fluid Dynamics
Medical Physics
url https://arxiv.org/abs/2603.25523