A New Concept of Liquid Xenon Time Projection Chamber for Medical Imaging
Fuente:
arXiv
Enregistré dans:
| Auteurs principaux: | , , |
|---|---|
| Format: | Preprint |
| Publié: |
2026
|
| Sujets: | |
| Accès en ligne: | |
| Tags: |
Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
|
| _version_ | 1866915893442772992 |
|---|---|
| author | Li, B. Ma, Y. Ni, K. |
| author_facet | Li, B. Ma, Y. Ni, K. |
| contents | Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to crystal-based detectors for positron emission tomography (PET). In this work, we present a new single-phase liquid xenon time projection chamber (TPC) concept optimized for medical imaging, employing combined scintillation and electroluminescence-based ionization readout to enable low-noise signal amplification and intrinsic depth-of-interaction measurement.
We evaluate the system-level performance of this detector concept using Monte Carlo simulations based on OpenGATE and Geant4, with direct comparison to conventional LYSO-based PET systems. The study focuses on detection sensitivity, energy-based event selection efficiency, and reconstructed spatial resolution. While LYSO detectors provide higher absolute stopping efficiency due to their higher density, liquid xenon detectors exhibit improved photopeak purity as a result of superior intrinsic energy resolution, leading to enhanced rejection of scattered events.
Point-source reconstruction studies demonstrate that the intrinsic three-dimensional position sensitivity of the liquid xenon TPC translates into a reconstructed spatial resolution of approximately 1~mm full width at half maximum (FWHM) at the system level, compared to approximately 4~mm for LYSO-based systems under comparable conditions. These results indicate that liquid-xenon-based PET detectors can achieve competitive or superior imaging performance, particularly for applications requiring high spatial resolution, large axial acceptance, and scalable detector geometries. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2603_25974 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | A New Concept of Liquid Xenon Time Projection Chamber for Medical Imaging Li, B. Ma, Y. Ni, K. Instrumentation and Detectors Medical Physics Liquid xenon time projection chambers offer a homogeneous detection medium with excellent intrinsic energy resolution, fast scintillation, and true three-dimensional position sensitivity, making them an attractive alternative to crystal-based detectors for positron emission tomography (PET). In this work, we present a new single-phase liquid xenon time projection chamber (TPC) concept optimized for medical imaging, employing combined scintillation and electroluminescence-based ionization readout to enable low-noise signal amplification and intrinsic depth-of-interaction measurement. We evaluate the system-level performance of this detector concept using Monte Carlo simulations based on OpenGATE and Geant4, with direct comparison to conventional LYSO-based PET systems. The study focuses on detection sensitivity, energy-based event selection efficiency, and reconstructed spatial resolution. While LYSO detectors provide higher absolute stopping efficiency due to their higher density, liquid xenon detectors exhibit improved photopeak purity as a result of superior intrinsic energy resolution, leading to enhanced rejection of scattered events. Point-source reconstruction studies demonstrate that the intrinsic three-dimensional position sensitivity of the liquid xenon TPC translates into a reconstructed spatial resolution of approximately 1~mm full width at half maximum (FWHM) at the system level, compared to approximately 4~mm for LYSO-based systems under comparable conditions. These results indicate that liquid-xenon-based PET detectors can achieve competitive or superior imaging performance, particularly for applications requiring high spatial resolution, large axial acceptance, and scalable detector geometries. |
| title | A New Concept of Liquid Xenon Time Projection Chamber for Medical Imaging |
| topic | Instrumentation and Detectors Medical Physics |
| url | https://arxiv.org/abs/2603.25974 |