From Energy Transition Pathways to Measurement Requirements: A Scenario-Based Study of Low-Voltage Grids

Fuente: arXiv
Enregistré dans:
Détails bibliographiques
Auteurs principaux: Zimmermann, Nane, Wagner, Lukas P., von Rönn, Luca, Strobel, Florian, Hüttmann, Paul, Gehlhoff, Felix
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866912989938974720
author Zimmermann, Nane
Wagner, Lukas P.
von Rönn, Luca
Strobel, Florian
Hüttmann, Paul
Gehlhoff, Felix
author_facet Zimmermann, Nane
Wagner, Lukas P.
von Rönn, Luca
Strobel, Florian
Hüttmann, Paul
Gehlhoff, Felix
contents Increasing penetration of electric vehicles, heat pumps, and rooftop photovoltaics is creating thermal and voltage stress in low-voltage distribution grids. This work links three German energy transition pathways (2025-2045) with state estimation performance requirements, evaluated on two SimBench reference networks across three equipment quality levels (good, medium, poor) and three VDE Forum Netztechnik/Netzbetrieb (VDE FNN) measurement constellations that differ in the availability of transformer and feeder-level instrumentation. Congestion is caused exclusively by transformer overloading and voltage-band violations. No individual line exceeds its thermal rating. Equipment quality is the primary factor: under good equipment, congestion remains nearly absent through 2045 (1/26 scenarios), under medium equipment it emerges from 2035 (10/26), under poor equipment from 2025 (25/26), reaching 208 % peak transformer loading. Without transformer instrumentation, voltage estimation errors remain at 6-35% regardless of smart meter penetration. Adding a single transformer measurement reduces errors by a factor of 3 to 24, achieving median errors below 1.1% under poor equipment. Per-feeder measurements achieve comparable accuracy and outperform the transformer-only configuration under poor equipment in rural networks (0.8% vs. 1.1%). In urban networks under poor and medium equipment, transformer and feeder-level instrumentation meet the VDE FNN voltage accuracy target without requiring customer-side sensors. These findings motivate prioritizing transformer instrumentation as an effective first step for grid observability and supplementing the current consumption-driven metering rollout with risk-based deployment criteria linked to local congestion exposure.
format Preprint
id arxiv_https___arxiv_org_abs_2603_28945
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle From Energy Transition Pathways to Measurement Requirements: A Scenario-Based Study of Low-Voltage Grids
Zimmermann, Nane
Wagner, Lukas P.
von Rönn, Luca
Strobel, Florian
Hüttmann, Paul
Gehlhoff, Felix
Systems and Control
Increasing penetration of electric vehicles, heat pumps, and rooftop photovoltaics is creating thermal and voltage stress in low-voltage distribution grids. This work links three German energy transition pathways (2025-2045) with state estimation performance requirements, evaluated on two SimBench reference networks across three equipment quality levels (good, medium, poor) and three VDE Forum Netztechnik/Netzbetrieb (VDE FNN) measurement constellations that differ in the availability of transformer and feeder-level instrumentation. Congestion is caused exclusively by transformer overloading and voltage-band violations. No individual line exceeds its thermal rating. Equipment quality is the primary factor: under good equipment, congestion remains nearly absent through 2045 (1/26 scenarios), under medium equipment it emerges from 2035 (10/26), under poor equipment from 2025 (25/26), reaching 208 % peak transformer loading. Without transformer instrumentation, voltage estimation errors remain at 6-35% regardless of smart meter penetration. Adding a single transformer measurement reduces errors by a factor of 3 to 24, achieving median errors below 1.1% under poor equipment. Per-feeder measurements achieve comparable accuracy and outperform the transformer-only configuration under poor equipment in rural networks (0.8% vs. 1.1%). In urban networks under poor and medium equipment, transformer and feeder-level instrumentation meet the VDE FNN voltage accuracy target without requiring customer-side sensors. These findings motivate prioritizing transformer instrumentation as an effective first step for grid observability and supplementing the current consumption-driven metering rollout with risk-based deployment criteria linked to local congestion exposure.
title From Energy Transition Pathways to Measurement Requirements: A Scenario-Based Study of Low-Voltage Grids
topic Systems and Control
url https://arxiv.org/abs/2603.28945