Enregistré dans:
Détails bibliographiques
Auteurs principaux: Jia, Feng, Arends, Gerrit Cornelis, Amrein, Philipp, Versteeg, Edwin, Klomp, Dennis W. J., Zaitsev, Maxim, Tax, Chantal M. W., Littin, Sebastian
Format: Preprint
Publié: 2026
Sujets:
Accès en ligne:https://arxiv.org/abs/2604.00896
Tags: Ajouter un tag
Pas de tags, Soyez le premier à ajouter un tag!
_version_ 1866908931073245184
author Jia, Feng
Arends, Gerrit Cornelis
Amrein, Philipp
Versteeg, Edwin
Klomp, Dennis W. J.
Zaitsev, Maxim
Tax, Chantal M. W.
Littin, Sebastian
author_facet Jia, Feng
Arends, Gerrit Cornelis
Amrein, Philipp
Versteeg, Edwin
Klomp, Dennis W. J.
Zaitsev, Maxim
Tax, Chantal M. W.
Littin, Sebastian
contents Introduction High performance gradients poses a promise for breast diffusion weighted imaging (DWI) but are restricted by physiological limits in whole body scanners. While local nonlinear coils offer higher amplitudes, they often suffer from severe gradient reduction near the chest wall. Methods We introduced an optimization framework incorporating a constraint to control anterior posterior gradient variation. A width based figure of merit was defined to evaluate performance regarding coil efficiency and minimum wire width. A prototype was constructed to validate the design methodology. Results The optimized coil achieved a 2.35 fold efficiency increase over standard linear coils. Compared to previous nonlinear designs, the new constraint reduced spatial variation by 35.7% and improved minimum efficiency near the chest wall by 2.6 fold. Experimental field maps matched simulations with errors under 8%. Discussion The proposed method effectively mitigates the trade-off between gradient strength and spatial uniformity along anterior posterior direction. By enhancing performance in the posterior breast region, the design addresses a critical limitation of previous local coils. Conclusion This framework enables the development of high performance, robust local gradient coils, facilitating the clinical implementation of advanced DWI protocols for breast cancer screening.
format Preprint
id arxiv_https___arxiv_org_abs_2604_00896
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Design of a double breast gradient coil with controlled anterior posterior gradient variation for diffusion weighted imaging
Jia, Feng
Arends, Gerrit Cornelis
Amrein, Philipp
Versteeg, Edwin
Klomp, Dennis W. J.
Zaitsev, Maxim
Tax, Chantal M. W.
Littin, Sebastian
Medical Physics
Introduction High performance gradients poses a promise for breast diffusion weighted imaging (DWI) but are restricted by physiological limits in whole body scanners. While local nonlinear coils offer higher amplitudes, they often suffer from severe gradient reduction near the chest wall. Methods We introduced an optimization framework incorporating a constraint to control anterior posterior gradient variation. A width based figure of merit was defined to evaluate performance regarding coil efficiency and minimum wire width. A prototype was constructed to validate the design methodology. Results The optimized coil achieved a 2.35 fold efficiency increase over standard linear coils. Compared to previous nonlinear designs, the new constraint reduced spatial variation by 35.7% and improved minimum efficiency near the chest wall by 2.6 fold. Experimental field maps matched simulations with errors under 8%. Discussion The proposed method effectively mitigates the trade-off between gradient strength and spatial uniformity along anterior posterior direction. By enhancing performance in the posterior breast region, the design addresses a critical limitation of previous local coils. Conclusion This framework enables the development of high performance, robust local gradient coils, facilitating the clinical implementation of advanced DWI protocols for breast cancer screening.
title Design of a double breast gradient coil with controlled anterior posterior gradient variation for diffusion weighted imaging
topic Medical Physics
url https://arxiv.org/abs/2604.00896