Saved in:
Bibliographic Details
Main Author: Scagnetto, Arjuna
Format: Preprint
Published: 2026
Subjects:
Online Access:https://arxiv.org/abs/2604.04485
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918429934485504
author Scagnetto, Arjuna
author_facet Scagnetto, Arjuna
contents ECG biometrics has been studied mainly on small cohorts and short inter-session intervals, leaving open how identification behaves under large galleries, external domain shift, and multi-year temporal gaps. We evaluated a 1D Inception-v1 model trained with ArcFace on an internal clinical corpus of 164,440 12-lead ECGs from 53,079 patients and tested it on larger cohorts derived from MIMIC-IV-ECG and HEEDB. The study used a unified closed-set leave-one-out protocol with Rank@K and TAR@FAR metrics, together with scale, temporal-stress, reranking, and confidence analyses. Under general comparability, the system achieved Rank@1 of 0.9506 on ASUGI-DB, 0.8291 on MIMIC-GC, and 0.6884 on HEEDB-GC. In the temporal stress test at constant gallery size, Rank@1 declined from 0.7853 to 0.6433 on MIMIC and from 0.6864 to 0.5560 on HEEDB from 1 to 5 years. Scale analysis on HEEDB showed monotonic degradation as gallery size increased and recovery as more examinations per patient became available. On HEEDB-RR, post-hoc reranking further improved retrieval, with AS-norm reaching Rank@1 = 0.8005 from a 0.7765 baseline. ECG identity information therefore remains measurable under externally validated large-scale closed-set conditions, but its operational quality is strongly affected by domain heterogeneity, longitudinal drift, gallery size, and second-stage score processing.
format Preprint
id arxiv_https___arxiv_org_abs_2604_04485
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle ECG Biometrics with ArcFace-Inception: External Validation on MIMIC and HEEDB
Scagnetto, Arjuna
Machine Learning
Artificial Intelligence
ECG biometrics has been studied mainly on small cohorts and short inter-session intervals, leaving open how identification behaves under large galleries, external domain shift, and multi-year temporal gaps. We evaluated a 1D Inception-v1 model trained with ArcFace on an internal clinical corpus of 164,440 12-lead ECGs from 53,079 patients and tested it on larger cohorts derived from MIMIC-IV-ECG and HEEDB. The study used a unified closed-set leave-one-out protocol with Rank@K and TAR@FAR metrics, together with scale, temporal-stress, reranking, and confidence analyses. Under general comparability, the system achieved Rank@1 of 0.9506 on ASUGI-DB, 0.8291 on MIMIC-GC, and 0.6884 on HEEDB-GC. In the temporal stress test at constant gallery size, Rank@1 declined from 0.7853 to 0.6433 on MIMIC and from 0.6864 to 0.5560 on HEEDB from 1 to 5 years. Scale analysis on HEEDB showed monotonic degradation as gallery size increased and recovery as more examinations per patient became available. On HEEDB-RR, post-hoc reranking further improved retrieval, with AS-norm reaching Rank@1 = 0.8005 from a 0.7765 baseline. ECG identity information therefore remains measurable under externally validated large-scale closed-set conditions, but its operational quality is strongly affected by domain heterogeneity, longitudinal drift, gallery size, and second-stage score processing.
title ECG Biometrics with ArcFace-Inception: External Validation on MIMIC and HEEDB
topic Machine Learning
Artificial Intelligence
url https://arxiv.org/abs/2604.04485