_version_ 1866917385940762624
author Pandey, A.
Gnanvo, K.
Kross, B.
McKisson, J.
Weisenberger, A.
Xi, W.
Dutta, J.
Shankman, N.
Scharenberg, L.
Alozy, J.
Angelis, Y.
Aune, S.
Ballabriga, R.
Bortfeldt, J.
Brunbauer, F.
Brunoldi, M.
Campbell, M.
De Oliveira, R.
Fanourakis, G.
Fernandez-Tenllado, J. M.
Flöthner, K. J.
Fiorina, D.
Gallinaro, M.
Garcia, F.
Giomataris, I.
Gomez, S.
Iguaz, F. J.
Janssens, D.
Kallitsopoulou, A.
Kovacic, M.
Legou, P.
Lisowska, M.
Liu, J.
Lupberger, M.
Manera, R.
Maniatis, I.
Mariscal, A.
Mauricio, J.
Meng, Y.
Muller, H.
Oliveri, E.
Orlandini, G.
Papaevangelou, T.
Picatoste, E.
Piller, M.
Pomorski, M.
Ropelewski, L.
Sampsonidis, D.
Sanuy, A.
Schneider, T.
Scorsone, E.
Sohl, L.
van Stenis, M.
Tsipolitis, Y.
Tzamarias, S. E.
Utrobicic, A.
Vai, I.
Veenhof, R.
Vitulo, P.
Wang, X.
White, S.
Zhang, Z.
Zhou, Y.
author_facet Pandey, A.
Gnanvo, K.
Kross, B.
McKisson, J.
Weisenberger, A.
Xi, W.
Dutta, J.
Shankman, N.
Scharenberg, L.
Alozy, J.
Angelis, Y.
Aune, S.
Ballabriga, R.
Bortfeldt, J.
Brunbauer, F.
Brunoldi, M.
Campbell, M.
De Oliveira, R.
Fanourakis, G.
Fernandez-Tenllado, J. M.
Flöthner, K. J.
Fiorina, D.
Gallinaro, M.
Garcia, F.
Giomataris, I.
Gomez, S.
Iguaz, F. J.
Janssens, D.
Kallitsopoulou, A.
Kovacic, M.
Legou, P.
Lisowska, M.
Liu, J.
Lupberger, M.
Manera, R.
Maniatis, I.
Mariscal, A.
Mauricio, J.
Meng, Y.
Muller, H.
Oliveri, E.
Orlandini, G.
Papaevangelou, T.
Picatoste, E.
Piller, M.
Pomorski, M.
Ropelewski, L.
Sampsonidis, D.
Sanuy, A.
Schneider, T.
Scorsone, E.
Sohl, L.
van Stenis, M.
Tsipolitis, Y.
Tzamarias, S. E.
Utrobicic, A.
Vai, I.
Veenhof, R.
Vitulo, P.
Wang, X.
White, S.
Zhang, Z.
Zhou, Y.
contents The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.
format Preprint
id arxiv_https___arxiv_org_abs_2604_04622
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area
Pandey, A.
Gnanvo, K.
Kross, B.
McKisson, J.
Weisenberger, A.
Xi, W.
Dutta, J.
Shankman, N.
Scharenberg, L.
Alozy, J.
Angelis, Y.
Aune, S.
Ballabriga, R.
Bortfeldt, J.
Brunbauer, F.
Brunoldi, M.
Campbell, M.
De Oliveira, R.
Fanourakis, G.
Fernandez-Tenllado, J. M.
Flöthner, K. J.
Fiorina, D.
Gallinaro, M.
Garcia, F.
Giomataris, I.
Gomez, S.
Iguaz, F. J.
Janssens, D.
Kallitsopoulou, A.
Kovacic, M.
Legou, P.
Lisowska, M.
Liu, J.
Lupberger, M.
Manera, R.
Maniatis, I.
Mariscal, A.
Mauricio, J.
Meng, Y.
Muller, H.
Oliveri, E.
Orlandini, G.
Papaevangelou, T.
Picatoste, E.
Piller, M.
Pomorski, M.
Ropelewski, L.
Sampsonidis, D.
Sanuy, A.
Schneider, T.
Scorsone, E.
Sohl, L.
van Stenis, M.
Tsipolitis, Y.
Tzamarias, S. E.
Utrobicic, A.
Vai, I.
Veenhof, R.
Vitulo, P.
Wang, X.
White, S.
Zhang, Z.
Zhou, Y.
Instrumentation and Detectors
The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.
title Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area
topic Instrumentation and Detectors
url https://arxiv.org/abs/2604.04622