Overview of Bayesian Solvers in EEG Distributed Source Models: Prior Selection, Algorithmic Implementation, and Depth Bias Reduction

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Lahtinen, Joonas, Koulouri, Alexandra
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866918432157466624
author Lahtinen, Joonas
Koulouri, Alexandra
author_facet Lahtinen, Joonas
Koulouri, Alexandra
contents Electroencephalography (EEG) source imaging aims to reconstruct the spatial distribution of neural activity within the brain from non-invasive scalp measurements. This inverse problem is severely ill-posed due to the low spatial resolution of EEG and the presence of measurement noise, necessitating robust regularization techniques. Bayesian approaches provide a principled framework for incorporating prior knowledge into the solution, where regularization naturally arises through prior distributions and their associated hyperparameters. In this work, we provide an overview of key Bayesian methods for EEG source imaging based on Gaussian, Laplace, and group Laplace priors, with particular emphasis on hierarchical models that promote sparsity. We analyze the connections between these hierarchical formulations and classical optimization techniques, and provide an analytical description of their implementation using expectation -maximization and alternating optimization algorithms. To address the issue of depth bias where deeper sources are systematically underestimated or mislocalized - we extend a statistical signal-to-noise ratio (SNR) framework to derive depth-weighted priors that account for differences in how strongly sources at different depths are reflected in the measurements. Finally, we illustrate the behaviour of the considered models through simulation studies involving sources at varying depths. The results highlight the impact of prior selection and depth weighting on reconstruction accuracy and demonstrate the importance of informed model design for depth-sensitive EEG source localization.
format Preprint
id arxiv_https___arxiv_org_abs_2604_05913
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle Overview of Bayesian Solvers in EEG Distributed Source Models: Prior Selection, Algorithmic Implementation, and Depth Bias Reduction
Lahtinen, Joonas
Koulouri, Alexandra
Numerical Analysis
Optimization and Control
60-08
G.1
Electroencephalography (EEG) source imaging aims to reconstruct the spatial distribution of neural activity within the brain from non-invasive scalp measurements. This inverse problem is severely ill-posed due to the low spatial resolution of EEG and the presence of measurement noise, necessitating robust regularization techniques. Bayesian approaches provide a principled framework for incorporating prior knowledge into the solution, where regularization naturally arises through prior distributions and their associated hyperparameters. In this work, we provide an overview of key Bayesian methods for EEG source imaging based on Gaussian, Laplace, and group Laplace priors, with particular emphasis on hierarchical models that promote sparsity. We analyze the connections between these hierarchical formulations and classical optimization techniques, and provide an analytical description of their implementation using expectation -maximization and alternating optimization algorithms. To address the issue of depth bias where deeper sources are systematically underestimated or mislocalized - we extend a statistical signal-to-noise ratio (SNR) framework to derive depth-weighted priors that account for differences in how strongly sources at different depths are reflected in the measurements. Finally, we illustrate the behaviour of the considered models through simulation studies involving sources at varying depths. The results highlight the impact of prior selection and depth weighting on reconstruction accuracy and demonstrate the importance of informed model design for depth-sensitive EEG source localization.
title Overview of Bayesian Solvers in EEG Distributed Source Models: Prior Selection, Algorithmic Implementation, and Depth Bias Reduction
topic Numerical Analysis
Optimization and Control
60-08
G.1
url https://arxiv.org/abs/2604.05913