| author | Zou, Sarah J. Chinn, Garry Ullah, Muhammad Nasir Levin, Craig S. |
| author_facet | Zou, Sarah J. Chinn, Garry Ullah, Muhammad Nasir Levin, Craig S. |
| contents | For accurate disease characterization using positron emission tomography (PET), it is desirable to image multiple radiotracers in a single scan. Conventional PET methods cannot do this due to the indistinguishable annihilation photons produced by different radiotracers. One approach is to label one radiotracer with a positron+prompt-gamma ($β^+\!\!-\!\!γ$) isotope producing triple coincidences, and another with a pure positron-emitting ($β^+$) isotope producing double coincidences. However, $β^+\!\!-\!\!γ$ emitters present challenges in correctly identifying the two annihilation photons, or equivalently, assigning the correct line-of-response (LOR) to triple-photon coincidence events. Here, we propose a maximum likelihood estimation (MLE) framework leveraging spatial, timing, and energy information to determine the most probable LOR. Simulation studies validated the method: simulations showed over 96\% and 94\% accuracy for LOR assignment of $β^+\!\!-\!\!γ$ emitters $^{22}$Na and $^{124}$I point sources, respectively. Furthermore, simulated phantom imaging of $^{22}$Na or $^{124}$I distributions alongside a $β^+$ emitter demonstrated that MLE LOR assignment achieved comparable image quality -- measured by contrast recovery coefficient (CRC) and cross-talk ratio (XR) -- to benchmark methods, where the prompt gamma was identified using an energy threshold ($\geq 650$ keV) for $^{22}$Na and as the highest-energy photon for $^{124}$I. |
| format | Preprint |
| id |
arxiv_https___arxiv_org_abs_2604_06500 |
| institution | arXiv |
| publishDate | 2026 |
| record_format | arxiv |
| spellingShingle | Maximum Likelihood Estimation Yields Accurate Line-of-Response Assignment for Positron + Prompt Gamma Ray Events in Multiplexed PET (mPET) Zou, Sarah J. Chinn, Garry Ullah, Muhammad Nasir Levin, Craig S. Medical Physics For accurate disease characterization using positron emission tomography (PET), it is desirable to image multiple radiotracers in a single scan. Conventional PET methods cannot do this due to the indistinguishable annihilation photons produced by different radiotracers. One approach is to label one radiotracer with a positron+prompt-gamma ($β^+\!\!-\!\!γ$) isotope producing triple coincidences, and another with a pure positron-emitting ($β^+$) isotope producing double coincidences. However, $β^+\!\!-\!\!γ$ emitters present challenges in correctly identifying the two annihilation photons, or equivalently, assigning the correct line-of-response (LOR) to triple-photon coincidence events. Here, we propose a maximum likelihood estimation (MLE) framework leveraging spatial, timing, and energy information to determine the most probable LOR. Simulation studies validated the method: simulations showed over 96\% and 94\% accuracy for LOR assignment of $β^+\!\!-\!\!γ$ emitters $^{22}$Na and $^{124}$I point sources, respectively. Furthermore, simulated phantom imaging of $^{22}$Na or $^{124}$I distributions alongside a $β^+$ emitter demonstrated that MLE LOR assignment achieved comparable image quality -- measured by contrast recovery coefficient (CRC) and cross-talk ratio (XR) -- to benchmark methods, where the prompt gamma was identified using an energy threshold ($\geq 650$ keV) for $^{22}$Na and as the highest-energy photon for $^{124}$I. |
| title | Maximum Likelihood Estimation Yields Accurate Line-of-Response Assignment for Positron + Prompt Gamma Ray Events in Multiplexed PET (mPET) |
| topic | Medical Physics |
| url | https://arxiv.org/abs/2604.06500 |