A Hidden Degeneracy in Two-Spot Models for Thermal X-Ray Pulse-Profile Fitting

Fuente: arXiv
Saved in:
Bibliographic Details
Main Authors: Zhao, Tong, Ge, Mingyu, Xu, Renxin
Format: Preprint
Published: 2026
Subjects:
Online Access:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1866908946181128192
author Zhao, Tong
Ge, Mingyu
Xu, Renxin
author_facet Zhao, Tong
Ge, Mingyu
Xu, Renxin
contents We discover an intrinsic degeneracy in the semi-analytic two-spot model for parameter inference in thermal X-ray pulse-profile modeling. Although this degeneracy exists in our simplified model with two small circular hot spots and without Doppler effects, it causes the likelihood surface of parameter inference based on ST-U and more complex models with Doppler effects to have multi-modal structures. Consequently, the posterior surface may also exhibit multi-modal structures if there is insufficient prior knowledge of parameters. Because of this, the inferred value of the neutron star radius can be biased even by $30\%$. This finding also provides a promising way to explain the multi-modal structures discovered in the evaluation of recovery performance using synthetic pulse-profiles that mimic the PSR J0030+0451 pulse-profiles~\citep{Vinciguerra2023,Vinciguerra2024}. Our work may have profound implications for the reanalysis of NICER data and the analysis of upcoming eXTP data.
format Preprint
id arxiv_https___arxiv_org_abs_2604_06654
institution arXiv
publishDate 2026
record_format arxiv
spellingShingle A Hidden Degeneracy in Two-Spot Models for Thermal X-Ray Pulse-Profile Fitting
Zhao, Tong
Ge, Mingyu
Xu, Renxin
High Energy Astrophysical Phenomena
We discover an intrinsic degeneracy in the semi-analytic two-spot model for parameter inference in thermal X-ray pulse-profile modeling. Although this degeneracy exists in our simplified model with two small circular hot spots and without Doppler effects, it causes the likelihood surface of parameter inference based on ST-U and more complex models with Doppler effects to have multi-modal structures. Consequently, the posterior surface may also exhibit multi-modal structures if there is insufficient prior knowledge of parameters. Because of this, the inferred value of the neutron star radius can be biased even by $30\%$. This finding also provides a promising way to explain the multi-modal structures discovered in the evaluation of recovery performance using synthetic pulse-profiles that mimic the PSR J0030+0451 pulse-profiles~\citep{Vinciguerra2023,Vinciguerra2024}. Our work may have profound implications for the reanalysis of NICER data and the analysis of upcoming eXTP data.
title A Hidden Degeneracy in Two-Spot Models for Thermal X-Ray Pulse-Profile Fitting
topic High Energy Astrophysical Phenomena
url https://arxiv.org/abs/2604.06654